background image

22

CIRWATT B 101-102

Instruction Manual

3�2�1�3�- Bill screen

By entering on that screen a bill closure will be forced. After 6 seconds it will go back to stand by 

screen

.

   

   bill

    

T

1

      

  

    done

    

T

1

         

PL

TIMER OFF

STAND BY 003

Figure 6:Bill screen�

3�2�1�4�- LED screen

On that screen the user can select if the LED pulse is related to active or reactive energy. With a long 

keystroke will go back to stand by screen.

   

   LED

    

T

1

      

  LED 

   ACT

.

     

T

1

         

PL

  LED 

  RACT

.

     

T

1

         

PC

PC

003

  000000

.

6

    

T

1

      

KWh

PL

003

  000000

.

6

    

T

1

    

R

 

KWh

PL

Note:

 It has a timer of 60 seconds

Figure 7:LED screens�

3�2�1�5�- Version screen

This screen shows the meter firmware version. With a long keystroke will go back to stand by screen.

   

   uERSIoN

    

T

1

      

 uER

  00

.

06

.

00

    

T

1

      

PL

Note:

 It has a timer of 60 seconds

003

  000000

.

6

    

T

1

      

KWh

PL

Figure 8:Version screen�

3�2�1�6�- CRC screen

This screen shows the firmware version CRC of the meter. With a long keystroke will go back to stand 

by screen.

   

   CRC

    

T

1

      

 CRC

    

1

819

     

T

1

      

PL

003

  000000

.

6

    

T

1

      

KWh

PL

Note:

 It has a timer of 60 seconds

Figure 9:CRC screen�

Summary of Contents for CIRWATT B 101-102

Page 1: ...INSTRUCTION MANUAL Single phase meter CIRWATT B 101 102 M98230701 03 21A...

Page 2: ...2 CIRWATT B 101 102 Instruction Manual...

Page 3: ...refully prior to connecting the unit Follow all installation and maintenance in structions throughout the unit s working life Pay special attention to the installation standards of the National Electr...

Page 4: ...N VERSION 13 2 12 1 IMPULSE OUTPUT S0 OPTIONAL 13 2 12 2 OUTPUT RELAY OPTIONAL 13 2 12 3 POTENTIAL FREE INPUT OPTIONAL 13 2 12 4 RS 485 PORT 13 2 13 REAL TIME CLOCK depending on the model 14 2 14 BATT...

Page 5: ...ICAL COMMUNICATIONS PORT 25 4 2 RS 485 COMMUNICATIONS MODEL B 102 25 4 3 MODBUS MEMORY MAP MODEL CIRWATT B 102 25 5 PARAMETERISATION AND READING SOFTWARE 27 6 INSTALLATION AND START UP 27 6 1 INSTALLI...

Page 6: ...of the devices are for illustrative purposes only and may differ from the original device SYMBOLS Table 2 Symbols Symbol Description In accordance with the relevant European directive Device covered...

Page 7: ...e prior to switching it on If any problem is noticed upon reception immediately contact the transport com pany and or CIRCUTOR s after sales service 2 PRODUCT DESCRIPTION CIRWATT Type B 101 102 is a s...

Page 8: ...Frequency 60 Hz B Without communications 0 Communications R1 R2 RS 485 2 Without inputs outputs 0 Expansion Optocoupler output 1 3 A 250 V Relay Output 3 Potential free input A Residential model B Mod...

Page 9: ...ds Maximum temperature 70 C 95 relative humidity without condensation 2 5 BUILD CHARACTERISTICS 2 5 1 GENERAL The meter has a class II protective insulating enclosure and double insulation As specifie...

Page 10: ...s detection is always made even if the energy meter has no power supply 2 5 6 TERMINAL BOX Screws The screws are mixed allowing the use of PZ2 Pozi drive no 2 and flat head screwdrivers The fastening...

Page 11: ...is shown on an LCD display that is specially designed for this application On it you can view all the information such as energy meters electrical parameters status indicators etc Figure 1 LCD Code li...

Page 12: ...urer s identification mark and place of manufacture Type designation and certification markings The number of phases and the number of conductors in the circuit to which it can be connected e g 2 wire...

Page 13: ...SE OUTPUT S0 OPTIONAL The energy meter has an impulse output with a 1000 imp kWh rate that supports inputs of up to 24 V 50 mA 2 12 2 OUTPUT RELAY OPTIONAL The device has a normally open relay type ou...

Page 14: ...face of the cover there is a profile for properly attaching and placing the optical heads 2 16 RESET There is a full reset mode that re establishes the default factory parameters on the unit and sets...

Page 15: ...of the first closure In addition the maximum average quarter hour active power calculation will be stored from the last closure maximeter corresponding to magnitude A The units will be expressed in W...

Page 16: ...ding period of the load curve is 60 minutes The load curve has no information gaps Therefore any periods with no measurements can be filled in with empty records 2 22 DAYLIGHT SAVING TIME The meter an...

Page 17: ...sword in IEC 62056 21 Mode C Device parameter configuration A password is used to read all the parameters and records It is also needed to synchronise the date time and to program the energy meter 2 2...

Page 18: ...and stored data will be deleted The following data will be maintained date and time battery status manufacturer set parameters and distributor set parameters pass words 9600 baud serial communications...

Page 19: ...5 2000 Environmental testing Part 2 5 Tests Test Sa Simulated solar radiation at ground level and guidance for solar radiation testing UNE 207010 2003 Bar coding application for the coding for electri...

Page 20: ...read button will freeze the display on the totalizer reading that is being shown at that moment Use short clicks to move manually through all the totalizer readings On devices set up as a simple acti...

Page 21: ...values screen On this screen the instant values are showed Those are voltage current active power reactive power With a long keystroke will go back to stand by screen INST T1 000239 0 T1 V PL 00000 00...

Page 22: ...ED T1 LED ACT T1 PL LED RACT T1 PC PC 003 000000 6 T1 KWh PL 003 000000 6 T1 R KWh PL Note It has a timer of 60 seconds Figure 7 LED screens 3 2 1 5 Version screen This screen shows the meter firmware...

Page 23: ...riff 2 5 8 2 000000 16 Reactive energy Q1 in tariff 3 5 8 3 000000 18 Total reactive energy Q2 6 8 0 000000 19 Reactive energy Q2 in tariff 1 6 8 1 000000 20 Reactive energy Q2 in tariff 2 6 8 2 00000...

Page 24: ...6 8 2 000000 56 Reactive energy Q2 in tariff 3 in the last bill closure 6 8 3 000000 58 Total reactive energy Q3 in the last bill closure 7 8 0 000000 59 Reactive energy Q3 in tariff 1 in the last bil...

Page 25: ...r there is a magnetic profile for the correct fastening and location of optical heads 4 2 RS 485 COMMUNICATIONS MODEL B 102 This type of communications method is used to create a communications bus fo...

Page 26: ...18 1816 Int 32 Reactive energy Q1 en VArh without decimals 0x0720 1824 Int 32 Reactive energy Q2 en VArh without decimals 0x0728 1832 Int 32 Reactive energy Q3 en VArh without decimals 0x0730 1840 Int...

Page 27: ...he DIN 43857 standard which specifies the dimensions and the mounting points Be aware that when the device is switched on the terminals may cause an electrical shock if touched and opening covers or r...

Page 28: ...E EN 50470 or Class 1 IEC 62053 21 Reactive energy Class 2 0 IEC 62053 23 Calculation and Processing Microprocessor 16 bit RISC Converter 16 Bits Memory Data RAM powered by lithium battery Setup event...

Page 29: ...t optional Hardware EN 62056 21 Baud rate 9600 bps Protocol EN 62056 21 Mode C Tamper detector Activation Tampering with the meter or connections Insulation Alternating voltage 4 kV RMS 50 Hz for 1 mi...

Page 30: ...ition contrary to the national electrical code or that surpasses the limits indicated in the technical and environmental features of this manual CIRCUTOR accepts no liability due to the possible damag...

Page 31: ...31 Instruction Manual CIRWATT B 101 102...

Page 32: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor es central circutor com...

Reviews: