SPECIFICATIONS

STD-302S 434 MHz

All ratings at 25 +/-10 °C unless otherwise noted

General characteristics

Item

Units

MIN

TYP

MAX

Remarks

Communication method

Simplex, Half-duplex

Emission class

F1D

Operating frequency range

MHz

429.25

429.7375

Operation temperature range

°C

-20

60

No dew condensation

Storage temperature range

°C

-30

75

No dew condensation

Frequency drift / year

ppm

-1

1

TX freq., RX Lo freq.

Initial frequency tolerance

ppm

-1.5

1.5

TX freq., RX Lo freq.

Dimensions

mm

30 x 50 x 9 mm

Not including antenna

Weight

g

25 g

Electrical specification <Common>

Item

MIN

TYP

MAX

Remarks

Oscillation type

PLL controlled VCO

Frequency stability

(-20 to 60°C)

ppm

-4

4

Reference frequency at 25 °C

TX/RX switching time

ms

15

20

DI/DO

Channel step

kHz

12.5

Data rate

bps

2400

4800

DO/DI

Max. pulse width

ms

15

20

DO/DI

Min. pulse width

us

200

DO/DI

Data polarity

Positive

DO/DI

PLL reference frequency

MHz

21.25

TCXO

PLL response

ms

30

60

from PLL setting to LD out

Antenna impedance 

Ω 

 

50 

 

Nominal 

Operating voltage

V

3.0

5.5

TX consumption current

mA

44

48

Vcc = 3.0 V

RX consumption current

mA

26

30

Vcc = 3.0 V

Transmitter part

Item

MIN

TYP

MAX

Remarks

RF output power 

mW 

12 

Conducted 50 Ω, 429.5 MHz 

Deviation

kHz

±1.7

±2.0

±2.3

PN9 4800 bps

DI input level

V

0

5.5

L= GND, H = 3 V- Vcc

Residual FM noise

kHz

0.17

DI=L, LPF=20 kHz

Spurious emission

dBm

-37

-27

Conducted

50 Ω

Adjacent CH power

dB

40

PN9 4800 bps

Occupied freq. bandwidth

kHz

8.5

PN9 4800 bps

Summary of Contents for STD-302

Page 1: ...cal and radio knowledge for setup and operation To ensure proper and safe operation please read this operation guide thoroughly prior to use Please keep this operation guide for future reference CIRCU...

Page 2: ...CIFICATIONS STD 302S 429 MHz 4 PIN DESCRIPTION 6 BLOCK DIAGRAM 9 DIMENSIONS 10 PLL IC CONTROL 11 PLL IC control 11 How to calculate the setting values for the PLL register 12 Method of serial data inp...

Page 3: ...gned to meet the basic specifications of Japanese ARIB STD T67 standard however it has not been certified for conformity with the technical regulations Users are required to perform the procedures for...

Page 4: ...illation type PLL controlled VCO Frequency stability 20 to 60 C ppm 4 4 Reference frequency at 25 C TX RX switching time ms 15 20 DI DO Channel step kHz 12 5 Data rate bps 2400 4800 DO DI Max pulse wi...

Page 5: ...anging channels Please make sure to optimize the timing The recommended preamble is more than 20 ms Antenna connection is designed as pin connection RF output power sensitivity spurious emission and s...

Page 6: ...TXSEL I TX select terminal GND TXSEL active To enable the transmitter circuits connect TXSEL to GND and RXSEL to OPEN or 2 8 V RXSEL I RX select terminal GND RXSEL active To enable the receiver circu...

Page 7: ...g input Interface voltage H 2 8 V L 0 V LD O PLL lock unlock indicator terminal Lock H 2 8 V Unlock L 0 V RSSI O Received Signal Strength Indicator terminal DO O Data output terminal Interface voltage...

Page 8: ...rmittent communication possible 8 429 2625 9 429 2750 10 429 2875 11 429 3000 12 429 3125 13 429 3250 14 429 3750 15 429 3875 16 429 3625 17 429 3750 18 429 3875 19 429 4000 20 429 4125 21 429 4250 22...

Page 9: ...OPERATION GUIDE OG_STD 302S 429M_v11e Circuit Design Inc 9 BLOCK DIAGRAM STD 302S 429MHz...

Page 10: ...OPERATION GUIDE OG_STD 302S 429M_v11e Circuit Design Inc 10 DIMENSIONS...

Page 11: ...equency is set externally by the controlling IC STD 302S has control terminals CLK LE DATA for the PLL IC and the setting data is sent to the internal register serially via the data line Also STD 302S...

Page 12: ...4 note fcomp fosc R Also this PLL IC operates with the following R N A and M relational expressions R fosc fcomp Equation 5 N INT n M Equation 6 A n M x N Equation 7 INT integer portion of a division...

Page 13: ...at this phase The PLL IC which operates as shown in the block diagram in the manual shifts the data to the 19 bit shift register and then transfers it to the respective latch counter register by judgi...

Page 14: ...n operating in the same channel a new PLL setting is not necessary it can receive data within 5 ms of switching 1 For data transmission if the RF channel to be used for transmission is set while still...

Page 15: ...el is not changed 5 ms 4 40 ms CPU Power on CH Data 5 5 ms 5 ms Check LD signal Check LD signal Normal status Status immediately after power comes on Channel change No channel change 4 2 Initialize th...

Page 16: ...614 509 38 18 429 3875 407 6875 407 6875 32615 509 39 19 429 4000 407 7000 407 7000 32616 509 40 20 429 4125 407 7125 407 7125 32617 509 41 21 429 4250 407 7250 407 7250 32618 509 42 22 429 4375 407 7...

Page 17: ...50 407 9250 32634 509 58 38 429 6375 407 9375 407 9375 32635 509 59 39 429 6500 407 9500 407 9500 32636 509 60 40 429 6625 407 9625 407 9625 32637 509 61 41 429 6750 407 9750 407 9750 32638 509 62 42...

Page 18: ...he PLL setting control board prepared by Circuit Design TEST DATA RSSI output level characteristic Measurement frequency 429 MHz Modulation unmodulated 25 C 5 C Signal level dBm RSSI mV 130 130 120 17...

Page 19: ...to the radio module Communication performance will be affected by the surrounding environment so communication tests should be carried out before actual use Ensure that the power supply for the radio...

Page 20: ...OG_STD 302S 429M_v11e Circuit Design Inc 20 OPERATION GUIDE REVISION HISTORY Version Date Description Remark 1 0 Jan 2015 1 1 Apr 2015 RSSI graph was revised P 18...

Reviews: