LP
E4
2
02
2.
03
e
n-
G
B
, I
D
-N
o.
: 1
63
-0
41
/E
www.imo.se
22
K.
• Mount the o-ring 007B and the seal can 005B
and tight the screws 007A with the correct
torque as stated on page 8.
M.
• Mount the valve 6000 with its o-ring 605 into
the back cover 551, lubricate thoroughly.
Note: shall always be pointing downwards.
O.
• Mount the pump into the connection frame in a
straight line.
P.
• Tighten the bolts 701 according to Tightening
Torque table.
L.
• Mount the idlers 202 into the pump body after
thoroughly lubricating them.
N.
• Mount the back cover 551 together with the
valve 6000 and gasket 556. Tight the bolts.
• Tight the bolts 453 with the correct torque that
can be found in Tightening Torque table.