background image

 
12.  If pump has mechanical seal, install inboard cover (4) on housing (1) without seal installation tool. 

 

 

CAUTION

ATTENTION

 

To maximize seal life, seal vent in cover must be oriented at 12:00 o'clock when pump is 
horizontally mounted in its installed position.  Vent orientation not critical when unit is 
vertically mounted.

 

 
13.  Install the four bolts (6) into inboard cover (4) and thread bolts into housing (1).  Torque bolts to values 

shown on assembly drawing. 

 

14.  Install O-ring (31) in groove in inlet head (2). 
 
15.  Install inlet head (2) onto housing (1) with cap screws (3 or 6). 
 
16. Install

 

key (13) into power rotor (7) keyway and coupling on shaft (7). 

 
17.  On pumps with external relief valves, install relief valve using cap screws (5) and O-ring (10). See 

figure 8. Relief valve can be installed in original position or facing 180° from original position. 

 

.  - INSTALLATION, ALIGNMENT AND TROUBLESHOOTING 

Install coupling to driver shaft and align pump and driver as detailed in Installation Manual, CA-1. 

After pump is connected to piping and inlet and outlet valves are open, be sure to vent air from seal 
chamber before starting pump by opening pipe plug at inboard end of pump until oil comes out. This will 
assure that seals are lubricated at startup.   

For detailed instructions regarding installation, alignment, operation and trouble shooting, see General 
Installation, Operation, Maintenance & Troubleshooting Manual, CA-1. 

 

J.  - FIELD AND FACTORY SERVICE AND PARTS 

 

Imo Pump maintains a staff of trained service personnel that can provide pump installation, pump start-
up, maintenance/overhaul and troubleshooting supervision as well as installation and maintenance 
training. 

Our factories provide maintenance as well as overhaul and test facilities in the event the user prefers to 
return pumps for inspection or overhaul.  Pumps that have been factory-overhauled are normally tested 
and warranted “as-new” for a period of one year from date of shipment.  

For either field service or factory overhaul assistance, contact your local Imo Sales Office or 
representative at the Technical/Customer Service Department in Monroe, NC, USA. 

Most pumps have minor repair kits available.  Minor Repair Kits are used to repair leaking seals, bad 
bearings and/or for re-assembly after pump tear-down.  They include (as applicable) pump shaft seals, 
packing, all gaskets/O-rings and bearings.  Since kits have all the necessary parts, it is preferred that 
they be purchased rather than selecting individual parts.  When parts are individually selected from the 
Parts List, some needed components are often overlooked.  In addition, mixing worn or used parts with 
new parts risks rapid wear and shortened service life from the new parts. 

 

 
 
 
 

 
 
 

Summary of Contents for IMO AA3G Series

Page 1: ...stallation Operation Maintenance and Troubleshooting Manual No SRM00046 this manual and associated component manuals supplied with the unit should be read thoroughly prior to pump installation start u...

Page 2: ...s Safety instructions where electrical safety is involved are identified by Safety instructions which shall be considered for reasons of safe operation of the pump and or protection of the pump itself...

Page 3: ...wording Imo Pump must assume the personnel assigned to operate and maintain supplied equipment and apply this instruction manual have sufficient technical knowledge and are experienced to apply sound...

Page 4: ...NS Never operate with water The pump is designed for liquids having the general characteristics of oil E 2 OPERATING LIMITS CAUTION ATTENTION Operating conditions such as speed fluid viscosity tempera...

Page 5: ...r 4 Bolt See Note 15 1 Retaining Ring 4 1 Inboard Cover 16X 1 Seal 5 4 Bolt Ext RV 19 1 Breakdown Bushing Steel Pumps Only 6 4 6 or 8 Bolt See Note 26X 1 O Ring 118 to 162 7 1 Power Rotor 31X 1 O Ring...

Page 6: ...isassembly of pump may make floor slippery and cause personal injury The following steps are required before starting any maintenance action a De energize and lock out power to driver and tag power co...

Page 7: ...16 off power rotor 7 b For Metal Bellows Type Seals see Fig 3 below Loosen set screw 3F and slide rotating assembly 3 from power rotor 7 NOTE IF ONLY REPLACING SEALS pump disassembly is complete For...

Page 8: ...rotating assembly 3 on power rotor shaft 7 For 95 sizes only be sure slots in rotating assembly 3 line up with seal return hole in power rotor shaft Tighten setscrew 3F Do not touch carbon seal face...

Page 9: ...instructions regarding installation alignment operation and trouble shooting see General Installation Operation Maintenance Troubleshooting Manual CA 1 J FIELD AND FACTORY SERVICE AND PARTS Imo Pump...

Page 10: ...Figure 3 AA3G 95 Iron Pump Assembly 8...

Page 11: ...Figure 4 AA3G 95 Steel Pump Assembly 9...

Page 12: ...Figure 5 AA3G 118 to 162 Iron ump Assembly 10...

Page 13: ...Figure 6 AA3G 118 to 162 Steel Pump Assembly 11...

Page 14: ...ivery of installation tool Material Steel Gray Iron Nylon VC or any hard material that will give a smooth finish A B C D E Overall Length OD ID Installation Angle Taper in in in Deg Deg 3G 95 1 1 8 62...

Page 15: ...IRCOR 1710 Airport Road 28110 PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Fax 1 704 289 9273 Email cc circor com Web www circorpt com 2020 CIRCOR Pumps North America LLC All rights reserve...