21
How to use Basic Post
E
Stop charging
While the unit is in charge status or is completely charged, the
user is available to finish the charge pressing the stop button.
Once the stop button is pressed, it starts to blink notifiying that
the energy transaction has finished.
At that time, the user is allowed to unplug the
cable from the EV.
Once the cable is disconnected from the EV, the LED
beacon turns back to green (A status, according to IEC
61851).
Until the status of stop button does not change from red to off, the charging
station is not available to start a new charging transaction, whenever it is
required.
D
Charged
When the EV is fully charged, it turns to Standby step, in which
both LED beacon and start button are green.
F
Error
The Charge Point has an error and it is not available to perform a charge
transaction.
In case that a charge transaction is in course, unplug the cable and wait until
the LED beacon and the start button turns into green to plug it again.