12 TECHNICAL DATA
CCL-PT3-SMART
AC INPUT
AC Power supply
3P + N + PE
AC Voltage
400V
AC
+/- 10%
Nominal input current
64 A
Nominal input power
44kW
Frequency
50 / 60 Hz
OUTPUT
PLUG A
PLUG B
Charge system
Mode 3
Mode 3
Sockets/ Plugs
Type 2
Type 2
Lock system
Yes
Maximum output power
22kW
22kW
Maximum output current
32A
32A
Output voltage range
400V
AC
(3P + N + PE)
ELECTRICAL PROTECTIONS
Overcurrent protections
MCB
Safety protection
RCD 30mA auto recovery (class A)
ENERGY METERS
Accuracy class in active energy
Class B
– EN50470-3
Accuracy class in reactive energy
Class 2
– EN62053-23
Meter standards
EN62052-11, EN62053-21, EN62053-23, EN61010-1
NETWORK
Ethernet
10/100BaseTX
GENERAL
Enclosure rating
IP54 / IK10
Enclosure material
Stainless steel
Operating temperature
-30 to +45ºC
Operating humidity
To 95% RH Non-condensing
RFID system
ISO / IEC14443A / B
Display
LCD Backlight double line text
Power limit control
Mode 3 PWM control according ISO / IEC 61851-1
Interface protocol
OCPP / XML
Net weight
65Kg
OPTIONAL DEVICES
Mobile communications
3G / GPRS
RCD protection
RCD class B
Overvoltage protection
Transient surge protector