background image

In climates where the pump may be exposed to frost or freezing, care must be taken to ensure
the pump is protected from damage. It is recommended that if the pump is not used during
winter period it should be drained completely and store pump in a dry location. Do not replace
the drain plug. Store it in a safe place when not use. An example would be store plug in the
filter tank basket.
When you are activate the pump ensure all seals and o-rings are in operational condition,
re-grease if necessary, replace if unsure of condition.
Check that the motor shaft moves freely before re-activation.

1. When connecting electric cables to the motor of the pump, be careful to correctly arrange
them inside the connection box, verify that no bits of cable are left inside the box on closing it.
See that the ground wire is correctly connected. When connecting the motor, follow the wiring
diagram supplied with the pump.
2. Be especially careful that no water enters the motor or electrical parts under voltage.
3. In the event that the planned use is not as specified, adaptations and supplementary
technical rules may be necessary.
4. Before starting the pump, verify the calibration of the electrical protection devices of the
motor and that the protections against electrical and mechanical contacts are correctly
positioned and attached.
5. It is advisable to follow the steps listed below before handling the pump in any way.
a) Turn off the voltage to the pump.
b) Lock starting devices.
c) Verify that there is no voltage in the circuits, including ancillary devices and auxiliary circuits.
d) Wait until motor stops completely.
The above list should be considered indicative and not binding for the purpose of safety,
specific safety rules may exist in particular regulations.

Assembly Instructions (some parts may be pre-assembled)

Follow the step below and the corresponding diagrams for assembly.

Step 1.

Place the strainer basket to the strainer housing. Be sure that the opening the basket is
aligned with the opening in the housing. Secure Lid

Step 2.

The water level of the inground swimming pool is lower than the water inlet of the pump.
In order to prevent water from flowing backward, this pump equipped a check valve.
First screw the adapter into the water inlet of the pump, and then install the connector
assembly.

6

Summary of Contents for CSPPD704

Page 1: ...s and Ordinances Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty Notice to Installer This...

Page 2: ...at the circuit breaker before servicing the pump Failure to do so could result in death or serious injury to service person pool users or others due to electric shock Pumps improperly sized or instal...

Page 3: ...cured GENERAL SAFETY RULES 1 The products mentioned in this manual are specially designed for the pre filtering and re circulation of water in swimming pools and spas 2 They are designed to work with...

Page 4: ...ruction concerning use of the appliance by a person responsible for their safety 16 The pump must be protected from running dry LOCATION The pump must be located as close as practical to the pool The...

Page 5: ...d on IEC 364 7 702 requirements RESPECT THE MINIMUM GAUGE GIVEN IN THE CHART OF THE TECHNICAL MANUAL Electrical Connection Check that the information on the nameplate corresponds to the power supply E...

Page 6: ...nded in a swimming pool when high speed is needed for maximum filtration at peak periods and whenever turbidity levels are high At other times switch to low speed For backwashing and vacuuming high sp...

Page 7: ...d adaptations and supplementary technical rules may be necessary 4 Before starting the pump verify the calibration of the electrical protection devices of the motor and that the protections against el...

Page 8: ...the case of any excessive high stop immediately and have it repaired CAUTION Owing to the complexity of the cases covered the instructions for installation use and maintenance contained in this manual...

Page 9: ...9b 647272971000 Impeller For CSPPD704 1 9c 647252771000 Impeller For CSPPD705 1 10 65431044080 O Ring 1 11 65028003000 Seal Assembly 1 12 647284803 Pump Housing 1 13 647284804 Motor Mounting Plate 1 1...

Page 10: ...or controls Faulty Pump shaft motor Replace the pump motor assembly Pump shaft is locked Check if the pump can be rotated by hand and remove any blockage Pump will not prime Suction air leak Make sur...

Page 11: ...ncorrect voltage Supply to be corrected by electrician A motor running hot to touch is normal Thermal overload protector will function to turn them off if there is an overload or excessive high temper...

Page 12: ......

Reviews: