background image

9

TROUBLESHOOTING

Problem

Cause

Solution

Low flow

Dirty filter

Backwash or clean cartridge

Dirty skimmer and pump
strainer

Clean skimmer and pump strainer

Suction air leak

Make sure water level is correct through
suction points. Ensure baskets and
strainers are free of debris. Tighten all
fittings/unions on the suction side of the
pump, remove and replace mechanical
seal

Closed valve or blocked line

Make sure water level is correct through
suction points. Ensure baskets and
strainers are free of debris. Tighten all
fittings/unions on the suction side of the
pump, remove and replace mechanical
seal

Pump does
not run

Not plugged in

Check the socket and power cord

GFCI/or main circuit breaker
tripped

Switch on the breaker. If it is immediately
tripped again,
There is a defect in pump or controls.

Faulty Pump shaft /motor

Replace the pump/motor assembly.

Pump shaft is locked

Check if the pump can be rotated by hand
and remove any blockage

Pump will
not prime

Suction air leak

Make sure water level is correct through
suction points. Ensure baskets and
strainers are free of debris. Tighten all
fittings/unions on the suction side of the
pump, remove and replace mechanical
seal

No water in the pump

Make sure the filter tank is full

Closed valves or blocked
lines

Open all valves in the system, clean
skimmer and pump basket, check pump
impeller of blockage

Motor
overload
cuts out

Motor not connected properly Have electrician check wiring
Low incoming voltage

Voltage at motors should be no more than
6% above or below nameplate voltage.
Have electrician check voltage; ensure
pump is not running on an extension cord.
Report low supplier to authorities.

Overload due to binding in
pump or wrong size impeller

Contact supplier

Noise pump Bad bearing

Have electrician replace

Summary of Contents for CSPPD704

Page 1: ...s and Ordinances Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty Notice to Installer This...

Page 2: ...at the circuit breaker before servicing the pump Failure to do so could result in death or serious injury to service person pool users or others due to electric shock Pumps improperly sized or instal...

Page 3: ...cured GENERAL SAFETY RULES 1 The products mentioned in this manual are specially designed for the pre filtering and re circulation of water in swimming pools and spas 2 They are designed to work with...

Page 4: ...ruction concerning use of the appliance by a person responsible for their safety 16 The pump must be protected from running dry LOCATION The pump must be located as close as practical to the pool The...

Page 5: ...d on IEC 364 7 702 requirements RESPECT THE MINIMUM GAUGE GIVEN IN THE CHART OF THE TECHNICAL MANUAL Electrical Connection Check that the information on the nameplate corresponds to the power supply E...

Page 6: ...nded in a swimming pool when high speed is needed for maximum filtration at peak periods and whenever turbidity levels are high At other times switch to low speed For backwashing and vacuuming high sp...

Page 7: ...d adaptations and supplementary technical rules may be necessary 4 Before starting the pump verify the calibration of the electrical protection devices of the motor and that the protections against el...

Page 8: ...the case of any excessive high stop immediately and have it repaired CAUTION Owing to the complexity of the cases covered the instructions for installation use and maintenance contained in this manual...

Page 9: ...9b 647272971000 Impeller For CSPPD704 1 9c 647252771000 Impeller For CSPPD705 1 10 65431044080 O Ring 1 11 65028003000 Seal Assembly 1 12 647284803 Pump Housing 1 13 647284804 Motor Mounting Plate 1 1...

Page 10: ...or controls Faulty Pump shaft motor Replace the pump motor assembly Pump shaft is locked Check if the pump can be rotated by hand and remove any blockage Pump will not prime Suction air leak Make sur...

Page 11: ...ncorrect voltage Supply to be corrected by electrician A motor running hot to touch is normal Thermal overload protector will function to turn them off if there is an overload or excessive high temper...

Page 12: ......

Reviews: