background image

CINO GROUP

P/N: YMAUB70010000R0

© Copyright PC Worth Int’l Co., Ltd. 
© Copyright Cino Group

FuzzyScan Fixed Mount Scanner Quick Start Guide - FM400 Series
International Edition, Rev. A

PC WORTH INT’L CO., LTD.

www.cino.com.tw

Cino  makes  no  warranty  of  any  kind  with  regard  to  this  publication,  including,  but  not  limited  to,  the 
implied  warranty  of  merchantability  and  fitness  for  any  particular  purpose.  Cino  shall  not  be  liable  for 
errors  contained  herein  or  for  incidental  consequential  damages  in  connection  with  the  furnishing, 
performance, or use of this publication. This publication contains proprietary information that is protected 
by  copyright.  All  rights  are  reserved.  No  part  of  this  publication  may  be  photocopied,  reproduced  or 
translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior 
written permission of Cino. All product information and specifications shown in this document may be 
changed without prior notice.

Disclaimer

Warranty

Cino  warrants  its  products  against  defects  in  workmanship  and  materials  from  the  date  of  shipment, 
provided that the product is operated under normal and proper conditions. The warranty provisions and 
durations  are  furnished  by  different  warranty  programs.  The  above  warranty  does  not  apply  to  any 
product which has been (i) misused; (ii) damaged by accident or negligence; (iii) modified or altered by the 
purchaser or other party; (iv) repaired or tampered by unauthorized representatives; (v) operated or stored 
beyond  the  specified  operational  and  environmental  parameters;  (vi)  applied  software,  accessories  or 
parts  are  not  supplied  by  Cino;  (vii)  damaged  by  circumstances  out  of  Cino’s  control,  such  as,  but  not 
limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty 
program and RMA procedures to return Cino for inspection.

Regulatory

FCC part 15B

EN55022, EN55024,
EN61000-3-2, EN61000-3-3

CNS13438

LED Eye Safety

IEC60825-1, EN60825-1

Industry Canada ICES-003

Summary of Contents for FuzzyScan FM400 Programming

Page 1: ...FUZZYSCAN FAMILY Quick Start Guide FM400 Series FIXED MOUNT SCANNER...

Page 2: ...ot only provides outstanding reading performance but also meets various demands for both industrial and general purpose applications This document provides a quick reference for installation and opera...

Page 3: ...NG signal outputs and external trigger input Pin No Signal Description I O Type Case FG Frame Ground 1 VCC I 2 Data USB Data I O 3 Data USB Data I O 4 GND Pin No Signal Description I O Type Case FG Fr...

Page 4: ...ur FuzzyScan There are two M3 mounting holes on the bottom of the chassis Please follow below procedures to mount your scanner Prepare two appropriate M3 screws minimal 4mm in depth and decide your de...

Page 5: ...nk per 1 second The scanner will turn on the light source to scan barcodes continuously before exit the test mode Keep scanner to read the same test barcode The scanner will count the Good Read number...

Page 6: ...nues to scan until the preset scan input time out is up You can adjust the time out duration from 100 milliseconds to 99 seconds to meet various application demands OK and NG Outputs The universal mod...

Page 7: ...l mode When the scanner receives an external trigger or a serial trigger ON command under level mode the scanner will turn on the light source to read barcodes until a good read is performed or the pr...

Page 8: ...SB HID Standard Mode USB HID Turbo Mode USB Com Port Emulation USB HID Interface Quick Set Record Suffix None RETURN TAB SPACE ENTER Keyboard Layout USA France Germany United Kingdom UK Canadian Frenc...

Page 9: ...TAB LF CR SPACE CRLF Baud Rate 38 4K BPS 1200 BPS 4800 BPS 19 2K BPS 600 BPS 2400 BPS 9600 BPS 300 BPS Data Frame 8 None 1 7 None 2 8 None 2 8 Odd 1 7 Odd 2 7 Odd 1 8 Even 1 7 Even 2 7 Even 1 8 Space...

Page 10: ...9 System Commands PROGRAM Enter Programming Mode END Exit Programming Mode System Information Factory Default Master Default PowerTool Host Link Save User Default User Default...

Page 11: ...N 00 7F FIN Postamble None 1 15 characters FIN 00 7F FIN Intermessage Delay None 1 99 x5 msec FIN 2 digits Intercharacter Delay None 1 99 x5 msec FIN 2 digits Interfunction Delay None 1 99 x5 msec FIN...

Page 12: ...character Delay None 1 99 x5 msec FIN 2 digits Interfunction Delay None 1 99 x5 msec FIN 2 digits Serial Response Time out None 200 msec 500 msec 1 sec 2 sec 5 sec User define value sec 0 1 2 3 4 5 6...

Page 13: ...er tone medium Buzzer tone high Buzzer tone extremely high Power on beep No Power on beep 0 1 2 3 4 5 6 Good Read Duration Short Medium Long Extremely long Extremely short 0 1 2 3 4 Presentation Sensi...

Page 14: ...le OK NG output Enable NG output Enable OK output Enable OK NG output 0 1 2 3 OK NG Signal Duration 10 msec 20 msec 30 msec 40 msec 50 msec 60 msec 70 msec 80 msec 90 msec 100 msec User define 1 99 x5...

Page 15: ...14 Option Codes 0 A 1 B 2 C 3 D 4 E 5 F 6 7 FIN Finish 8 9 END Exit...

Page 16: ...ecifications shown in this document may be changed without prior notice Disclaimer Warranty Cino warrants its products against defects in workmanship and materials from the date of shipment provided t...