background image

 

4

Use FuzzyScan in PAIR Mode 

Ensure the battery is fully charged. Please refer to the section of 

Preparations before Using

 for details. 

 

Please choose your desired interface cable, then plug it into the host 
interface port of the smart cradle and connect it to the host device.   

 
 
 
 
 
 

 

Turn on the power of your host device. 

 

Please note that if the scanner is shipped together with a smart cradle, 
they are pre-paired already. You will see the link indicator of scanner 
gives 1 blue blink per 2.5 seconds and the central indicator of smart 
cradle turns steady blue. If the scanner and smart cradle just give 

alternative red and green blinks

 (“

Uninstall

” state), please follow step 

5 to establish the connection between scanner and smart cradle. 
 
Scan “PAIR mode” command. The status indicator of scanner will turn 
steady red immediately. 

 

 

Uninstall  

 PAIR 

Mode 

 

Place the scanner on the smart cradle, then you will hear one short beep 
to indicate the pairing process is activated. The scanner will emit 
continuous short clicks and the link indicator of scanner will flash blue 
quickly during the pairing process. When you hear 4 beeps in ascending 
tone, the pairing process is completed. You will see that the link indicator 
of scanner gives 

1 blue blink per 2.5 seconds

 and the central indicator 

of the smart cradle turns 

steady blue

.  

 
If the scanner pairing process failed or it’s not placed on the smart cradle 
within 20 seconds, you will hear 2 “Di-do Di-do” beeps to warn the failure 
of pairing, the scanner will return to uninstall state automatically. 

 

Scan the corresponding host interface quick set command to complete 
the installation. 

The default host interface of smart cradle is preset to 

USB HID

. If you 

want to set the host interface to 

USB COM

, you have to install the 

USB virtual COM driver into your host device before using the 
scanner. Please visit CINO website to download the driver

 

 

USB 

PS/2 

RS232 

Summary of Contents for FuzzyScan F680BT

Page 1: ......

Page 2: ...standing reading performance but also delivers the convenience and freedom of mobility It s ideal for a broad range of applications to unleash your productivity with ease This document provides a quic...

Page 3: ...before its first use Ensure the battery contacts of the battery pack are facing the charging contacts inside the battery cavity Slide the battery pack into the battery cavity until hearing a click sou...

Page 4: ...le not only provides the Bluetooth radio link with the scanner but also offers the legacy cabled interfaces to the host device including USB HID USB COM PS 2 DOS V Keyboard Wedge and RS232 Serial PICO...

Page 5: ...the scanner on the smart cradle then you will hear one short beep to indicate the pairing process is activated The scanner will emit continuous short clicks and the link indicator of scanner will fla...

Page 6: ...install PICO Mode Place the scanner on the smart cradle then you will hear one short beep to indicate the pairing process is activated The scanner will emit continuous short clicks and the link indica...

Page 7: ...skey you will be requested to enter the Passkey PIN on the remote host Please enter the Passkey PIN accordingly by scanning the Option Code page 13 and then scan the FIN Finish to end the Passkey entr...

Page 8: ...licks and the link indicator of the scanner will flash blue quickly during the radio connecting process If the Passkey PIN is requested please enter 00000000 default setting The scanner will emit 4 be...

Page 9: ...x on the discovered Bluetooth devices If the Passkey PIN is requested please enter 00000000 default setting You will see Serial Port on F L A xxxBT xxxx Please double click this SPP service to establi...

Page 10: ...hear 4 beeps in ascending tone to indicate the radio connection rebuilt and the link indicator of scanner will give 1 blue blink per 2 5 seconds At the same time all stored scanned data will be transm...

Page 11: ...rage is full If the storage is full you will hear 2 long beeps and the status indicator will give 2 red blinks to indicate out of storage To terminate the batch scanning please scan the Exit Batch Sca...

Page 12: ...Transmit Stored Data The scanner is preset to transmit all stored data by scanning the Transmit Stored Data command During the transmission the scanner will emit continuous short clicks and the link...

Page 13: ...ey Host Interface Quick Set Smart Cradle only RS232 Serial USB HID Standard Mode PS 2 DOS V KBW Standard Mode PS 2 DOS V Keyboard Replacement USB HID Turbo Mode PS 2 DOS V KBW Turbo Mode USB Com Port...

Page 14: ...ormation Paging Master Default PowerTool Host Link Sleep Save Configuration Factory Default Power Off Clone Operation Mode Quick Set Trigger Mode Presentation Mode Option Codes 0 8 4 C 1 9 5 D 2 A 6 E...

Page 15: ...red blinks 8 beeps Good read 1 green blink 1 good read beep Under Configuration Steady red Off Uninstall state Alternative red and green blinks Off Upgrade state Steady red Short click Time out warni...

Page 16: ......

Reviews: