GE AC Instalation and operation manual V10.docx
56
/ 63
9.
HUMAN MACHINE INTERFACE
CINERGIA delivers, within the scope of the supply, a Human Machine Interface software that
communicates with the equipment using MODBUS protocol. This application is compatible
on
Windows 10/Windows 7/Windows XP. The software can be installed by executing Setup.exe file
in Administrator Mode and following the instructions of the application.
To connect Cinergia units to a PC, follow these steps:
-
Connect a standard RJ45 Ethernet cable to terminal X15. The unit can be connected
directly either to a computer or to a router (wired or wireless). If the CINERGIA unit is
connected through a router, several computers could be connected to the unit at the
same time.
-
Check the IP address of CINERGIA unit in the LCD Touchscreen pressing the button
“About”.
-
Check the computer’s Ethernet configuration panel and make sure that both the
computer and the CINERGIA unit are in the same subnetwork. For instance, if the
CINERGIA unit IP address is 192.168.55.237 the computer Ethernet configuration shall
be:
a)
Computer IP address: 192.168.55.XXX (XXX can be any address different from
237 and different from any other device in the same network)
b)
Subnet mask: 255.255.255.0
c)
Gateway and DNS configuration are not needed for a connection with a
CINERGIA unit
-
Run the graphical user interface delivered by CINERGIA, write the IP address of the unit
to be connected and press the Connect button.
If there is an error when trying to run CINERGIA application please check the
compatibility mode of your computer. For instance in a Windows 7 computer, right
click CINERGIA application → Proper es; go to Compa bility panel and check the box
Run this program in compatibility mode; and select the operating system of your
computer.
Read the document “
Connecting CINERGIA units to a PC v2
” for more information.
The software is based on a Tab Dialog, in which each tab has one of the following purposes:
-
OPERATION
-
ALARM
-
SUPERVISION
-
AC OPERATION
-
FAULTS
Further information of each tab can be found in the following sections.