Placement of Model
Ventilation
Your incubator must be located in an indoor area. The area must be
clean and ventilated. Ideal distance from walls is 50 cm. Don’t place
machine close to the walls of incubation room. The Incubator must not
be exposed to direct sunlight and not subject to splashes of water or
high humid conditions.
Place your incubator to a flat surface far from doors and windows.
Ideal incubation room temperature is 20–25
°°°°
C
. Wide temperature
variations in the room affect your incubation results. If your area is
very cold or hot, use air condition system in room.
Be sure that room is being ventilated adequately for fresh air
intake.
Embryo needs proper oxygen levels and produce carbon dioxide during incubation.
To supply oxygen in proper level and remove carbon dioxide, ventilation is
essential.
In CT series models, ventilation is supplied automatically with fan and air-in / air out
holes. Air in/out ventils are adjustable.
Air in/out ventils can be adjusted by left / right turn to decrease air in/out by
considering egg amount in your incubator.
Caution!
Never close air- in / out holes.
Caution!
Always keeps air- in / out holes fully open during hatching period.
Caution!
Never make animal breeding in incubation room.
Caution!
Be sure incubation room has adequate air intake.
Caution!
Don’t let room temperature below 15
°°°°
C and above 30
°°°°
C
Caution!
Don’t let reaching of animals and insects to the incubator.
Caution!
Don’t let accessing of children or person that have physically or mentally
problems to the incubator.
Air out
Air in
50cm
50cm
50cm