CT SERIES
Humisonic
TM
Automatic Humidity Control
Humidity adjustment in incubators is for
providing adequate water loss from eggs
. And also
high humidity levels for last 2-3 day
are
also very important.
Egg needed to lose between 13-16 % water depending on the species during incubation period. Weighing of eggs
during incubation is most trustable method to find proper humidity needed to good hatching results for particular poultry species.
Different from temperature, short term humidity changes during incubation are not important. Providing an average humidity in desired level
during all incubation period is enough to achieve good results. However, high humidity levels during hatching period ( last 2-3 day) is very
important. When the chick started to hatch, inner membrane of egg dries quickly. This makes membranes harden and chick can stick to
shell. To prevent drying of membranes, humidity must be adjusted to high levels depending on species for last 2-3 day of incubation.
Installation
-
Connect Humisonic
TM
reservoir right side of the incubator.
-
Place stainless Humisonic
TM
unit to the bottom of reservoir.
-
Connect top reservoir 4 lt with Humisonic
TM
reservoir by flexible hose.
-
Connect Humisonic
TM
cable to Adapter and adapter to the control panel.
-
The float valve in Humisonic
TM
reservoir will keep water level 1 - 2 cm above water level sensor.
Humisonic
TM
Adapter
1-2 cm
level sensor
Humisonic
TM
unit
Humisonic
TM
reservoir
Humisonic
TM
cable
Flexible hose
Float valve
Reservoir
4 lt
CAUTION!
Don’t use hard and limy waters for humidifier system and for humidity tray and change humidifier disks periodically.
Humisonic
TM
humidifier units design for on – off work. Don’t let it working continuously for long time. This will decrease service
life of unit and power adapter.