Precautions for mounting (       Caution) 

 

Use the PLC in an environment that meets the general specifications given in this manual.  
 
Using this PLC in any environment outside the range of the general specifications could 
result in electric shock, fire, malfunction, or damage to or deterioration of the product. 
 
Please ensure that each module is installed correctly in its place. Loosely or incorrectly 
installed pieces may result in malfunction, failure, or free-fall. 
 
The PLC power supply should be turned off before mounting the module. Not doing so could 
cause an electric shock or damage to the device. 
 
Install I/O devices or extension connectors correctly. If they are installed incorrectly, it may 
result in an input or output failure. 
 
Do not convey direct vibration into the PLC. Doing so could cause electric shock, fire or 
malfunctions. 
 
After wiring work, please make sure to close the terminal cover before turning on the power 
for the PLC system. 

 

Precautions for wiring (       Warning) 

 

Make sure to check the device’s rated voltage and circuit arrangement before wiring. Failure 
to do so may cause electric shock or damage to the device. 
 
Make sure to close the terminal cover before turning on the power of the PLC system after 
wiring work. Failure to do so may cause electric shock. 

 

Precautions for wiring (       Caution)

 

 

 

Make sure to check the device’s regular voltage and sequence of terminals. Failure to do so 
may cause fire, electric shock and malfunctions. 
 
Make sure to tighten the screw with standard torque. Loose connections may cause a short 
circuit, fire, or malfunctions. 
 
When grounding the FG ground terminals, be sure to conduct the product with at least D 
type (Class 3) grounding. Not doing so could result in electric shock or malfunctions. 
 
When wiring, make sure that wiring debris does not enter the module. Failure to do so may 
cause fire, equipment damage, or malfunctions. 

 

 

 

Summary of Contents for CM1-EP01A

Page 1: ... 1 Expansion CM1 EP01A CM1 EP02A CM1 EP03A CM1 EP02F G ...

Page 2: ... 2 Contents General Specifications 21 Performance Specifications 22 Wiring 22 Expansion Configuration 23 Appearance and Dimensions 26 Product Warranty 27 ...

Page 3: ...e or part of this manual without written permission from CIMON Inc is prohibited Safety symbols are classified into two categories WARNING and CAUTION Warning This symbol describes situations that could cause major or fatal injury to the user Caution This symbol describes situations that may cause minor injury or damage to the device SAFETY SYMBOLS USED IN THIS PRODUCT MEAN This symbol warns the u...

Page 4: ...nnot detect such as in the relay or TR terminal Build an extra monitoring circuit that will monitor any output signal that could cause serious accidents A greater than normal current passed through the PLC for an extended period of time or a short circuited load flowing through the output module may cause a fire Build a circuit that turns on the external power supply after the PLC power supply is ...

Page 5: ...s After wiring work please make sure to close the terminal cover before turning on the power for the PLC system Precautions for wiring Warning Make sure to check the device s rated voltage and circuit arrangement before wiring Failure to do so may cause electric shock or damage to the device Make sure to close the terminal cover before turning on the power of the PLC system after wiring work Failu...

Page 6: ...run and repair Caution Do not dissociate the PCB from the module s casing or make any modifications to the device Doing so may cause fire electric shock or malfunction When mounting or separating the module make sure to turn off power to the PLC and all other devices Failure to do so could cause an electric shock or malfunctions Use radio walkie talkie or cell phone devices at least 30 cm away fro...

Page 7: ... 0 5G Shock Max shock Acc 147 m s 2 15G Time 11 ms Pulse wave Half sine wave pulse 3 times in X Y Z IEC 61131 2 Noise Square Wave Impulse Noise 2 kV CIMON Standard Electrostatic Discharge 4 kV Contact 8 kV Air IEC 61131 2 IEC 61000 4 2 Radiated Electromagnetic Field 80 1000 MHz 10 V m IEC 61131 2 IEC 61000 4 3 Fast Transient Burst Noise Voltage CPU Power 2 kV IEC 61131 2 IEC 61000 4 4 Digital Anal...

Page 8: ...ts 3 Ports 2 Ports Standard 10 BASE T 10 100 BASE T TX 100 BASE FX Communication Speed 10 Mbps 10 100 Mbps 100 Mbps Transmission Method Half Duplex Distance of Maximum Communication Node Node 100 m 100 m 2 km Maximum Expansion Bases 16 Bases 31 Bases Depends on the CPU module Loader Port X O Mini B USB Performance Specifications Wiring ...

Page 9: ...if number of expansion bases is different from the setting number an error may occur The module number is counted continually from the previous base Recommendations on using USB Cable 1 Recommended to use CIMON s shielded cable within 3m length 2 In case of using PC that is vulnerable to noises it is recommended to use a USB Hub or Isolator Expansion Configuration ...

Page 10: ...tch No of Bases Rotary Switch Rotary Switch Exp No 1 1 Exp No 1 0 1 Exp No 2 2 Exp No 2 0 2 Exp No 3 3 Exp No 3 0 3 Exp No 4 4 Exp No 16 1 6 Exp No 14 D Exp No 15 E Exp No 30 3 0 Exp No 16 F Exp No 31 3 1 EP02F G Module with XP1S XPnF UPnF CPU No of Bases Rotary Switch Exp No 1 0 Exp No 2 1 Exp No 3 2 Exp No 4 3 Exp No 14 D Exp No 15 E Exp No 16 F Expansion Configuration ...

Page 11: ...er Base No Hexadecimal number 2 Characters Slot No Hexadecimal number 2 Characters Example No of Base No of Slot Format Local Base 5 h0005 or 5 Expansion No 1 0 h0100 Expansion No 2 3 h0203 Expansion No 9 8 h0908 Expansion No 10 9 h0A09 Expansion No 15 10 h0F0A Expansion No 16 11 h100B Expansion Configuration ...

Page 12: ... 12 Appearance ...

Page 13: ... 13 Unit mm Dimensions ...

Page 14: ...orage exposure to moisture or dampness unauthorized modifications unauthorized repair misuse neglect accident alteration improper installation or other acts which are not the fault of CIMON including damage caused in shipping Our warranty also does not apply to any product that has been damaged by external causes such as fire flood sand dirt lightning acts of God battery leakage theft blown fuses ...

Page 15: ...ON INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHTS OR THE ACCURACY RELIABILITY QUALITY OR CONTENT IN OR LINKED TO THE PRODUCTS CIMON AND ITS AFFILIATES AND SUPPLIERS DO NOT WARRANT THAT THE PRODUCTS ARE SECURE FREE FROM BUGS VIRUSES INTERRUPTION ERRORS THEFT OR DESTRUCTION FURTHER CIMON DOES NOT WARRANT ACCESS TO THE INTERNET OR TO ANY OTHER SERVICE CONTENT OR DATA TRANSMITTED THROUGH THE PRODUCT...

Page 16: ... LIABLE FOR ANY OF THE FOLLOWING A INDIRECT SPECIAL INCIDENTAL PUNITIVE OR CONSEQUENTIAL DAMAGES B DAMAGES RELATING TO FAILURES OF TELECOMMUNICATIONS THE INTERNET ELECTRONIC COMMUNICATIONS CORRUPTION SECURITY LOSS OR THEFT OF DATA VIRUSES SPYWARE LOSS OF BUSINESS REVENUE PROFITS OR INVESTMENT OR USE OF SOFTWARE OR HARDWARE THAT DOES NOT MEET CIMON SYSTEM REQUIREMENTS THE ABOVE LIMITATIONS APPLY EV...

Page 17: ...MEMO ...

Page 18: ...1 BCP65316 CIMON CO LTD Seoul Address 11F M State 114 Beobwon ro Songpa gu Seoul Republic of Korea 05854 Tel 82 2 480 8587 USA Address CIMON Inc 2435 W Horizon Ridge Pkwy 100 Henderson NV 89052 Tel 1 702 820 1060 Homepage www cimon com ...

Page 19: ...고객서비스 정보 회 사 명 주 싸이몬 CIMON CO Ltd 홈페이지 www cimon co kr 본 사 경기도 성남시 분당구 벌말로 48 야탑동 272 1 케이디티 빌딩 전 화 1899 8191 팩 스 031 724 4789 담 당 품질보증팀 팀장 이 메 일 cs cimon com ...

Reviews: