Link 50 - 55
1-2009
36
Position the distribution piping T5 and feed piping T4 so as to avoid the risk of
suffering damage or breakage during spraying. It may be needed to shorten the
pipes.
IN CASE OF A PIPE BURST:
1 - Stop the tractor and remove the key from the control panel.
2 - Close the 2 taps of distributor (P9).
3 - Move the 3-way cock (P2) lever to position “B”, filling.
4 - Close the cock with pressure regulating handgrip (P5) (turn it clockwise).
5 - Repair or replace the broken pipes (for the elimination of these parts, please follow the current
regulations).
5.3.3 - E.P.A. Control Unit
Act in a similar way as indicated for installing the electric control power plant (E10)
(see Paragraph 5.3.1.)
Position the electric cables in such a way to prevent them from getting torn during
the treatment.