1-2009
25
Link 50 - 55
E10. CONTROL UNIT
00215
P11
T5
P9
T4
®
+
-
ON
Remote Control
H O
2
ON
OFF
OFF
Pump
00907
00216
E9
E10
P11
T5
T4
®
+
-
ON
Remote Control
H O
2
ON
OFF
OFF
Pump
It is electrically connected to the distributor with
2 motorised solenoid valves (E9) and to the main
socket of the tractor (Lighter tap).
The 2 lever switches, controlling the solenoid
valves (E9), have to be set to “ON” for opening
and to “OFF” for closing. The control unit is
equipped with a bayonet support to be inserted
in the bracket provided. This must be mounted on
the tractor, within the driver’s reach. When the
machine isn’t hitched to the tractor, it must be
placed in the position foreseen on the forward part of the machine frame.
In the versions with the additional agitation pump, the gearbox is equipped with a RED warning light
indicating an insufficient pressure : in the versions with the pressure control electrovalve, the gearbox
is equipped with a joystick for moving the electrovalve and for adjusting the delivery pressure control.
E9.
ELECTRICAL DISTRIBUTOR WITH TWO SOLENOID VALVES
It is connected with the feeding pipe (T4), the
distribution pipes (T5) and the electrical unit
(E10), which is fastened on the tractor. The
solenoid valves open and close themselves,
according with the action carried out on the
electrical control unit switches.
In the E.P.A. versions, the controls of the cross
section solenoid valves are situated on the
electronic control unit (see specific manual).
P9.
MANUAL DISTRIBUTOR WITH 2 LEVER-OPERATED TAPS
(for versions in which this envisaged)
It connects the feeding pipe (T4) to the distribution
piping (T5). It remote-controls the closing and
opening of the pulverising. The mount bracket,
supplied with the machine, must be secured to the
tractor within the driver’s reach. When the machi-
ne is not hitched to the tractor, it must be placed
on the forward part of the sprayer’s frame.
Each tap permits the spraying from a single side
of the head: to the right and to the left respectively.
They are
open
when the levers are set in the
vertical
position.
They are
closed
when the levers are
horizon-
tal
.