Manual 0-5406 7-3 SERVICE
Power Source Problems Cont'd
Description
Possible Cause
Remedy
7
No Shielding Gas flow in TIG
mode.
A
Shielding Gas hose is
damaged.
A
Replace or repair the Shielding
Gas Hose.
B
Shielding Gas passage
contains impurities.
B
Turn Off Shielding Gas supply at
cylinder or source and disconnect
gas hose from the rear of the
power source and blow out
impurities.
!
WARNING
1. Wear approved face
shield or safety goggles.
S i d e s h i e l d s
recommended.
2. Wear proper body
protection to protect skin.
C
Shielding Gas
Regulator turned Off.
C
Turn On the Shielding Gas
Regulator and adjust the flow rate
to suit the welding job. Refer to
Table 5-5 on page 5-7.
D
Empty Shielding Gas
cylinder.
D
Replace Shielding Gas cylinder.
E
Tig Torch 8 Pin
Control Plug is not
connected correctly or
the Tig Torch Trigger
Switch, 8 Pin Control
Plug or Lead is faulty.
E
Ensure that the 8 Pin Control Plug
is correctly connected or repair
or replace the Tig Torch Trigger
Switch or 8 Pin Control Plug or
Lead.
F
Shielding Gas Valve in
Power Source is not
operating correctly.
F
Have an Accredited Cigweld
service provider repair or replace
the Shielding Gas Valve.
8
Gas flow continues after
the torch trigger switch has
been released (TIG mode).
A
Post flow is active in
TIG mode.
A
Post Gas Flow time is not
adjustable and cannot be adjusted
independently of the Welding
Current. The Post Flow time range
is approximately 1 to 8 seconds
depending on the Welding
Current Setting. For example if
the Welding Current is set to 10
amps the Post Gas Flow time will
be approximately 1 second. If
the Welding Current is set to 200
Amps the Post Gas Flow time will
be approximately 8 seconds.
B
Shielding Gas valve
has jammed open due
to impurities in the
gas or the gas line.
B
Have an accredited CIGWELD
service provider repair or replace
shielding gas valve.
Summary of Contents for WELDSKILL 200HF
Page 22: ...OPERATING MANUAL 200HF INSTALLATION 3 4 Manual 0 5406 This Page Intentionally Blank ...
Page 28: ...OPERATING MANUAL 200HF OPERATION 4 6 Manual 0 5406 This Page Intentionally Blank ...
Page 38: ...OPERATING MANUAL 200HF SERVICE 5 10 Manual 0 5406 This Page Intentionally Blank ...
Page 56: ...KEY SPARE PARTS 8 2 Manual 0 5406 OPERATING MANUAL 200HF This Page Intentionally Blank ...
Page 59: ...OPERATING MANUAL 200HF This Page Intentionally Blank ...