5.03 TIG (GTAW) Basic Welding Technique
Gas Tungsten Arc Welding (GTAW) or TIG (Tungsten Inert Gas) as it is commonly referred to, is a welding
process in which fusion is produced by an electric arc that is established between a single tungsten (non-
consumable) electrode and the work piece. Shielding is obtained from a welding grade shielding gas or welding
grade shielding gas mixture which is generally Argon based. A filler metal may also be added manually in some
circumstances depending on the welding application.
Welds Made With or Without
Addition of Filler Metal
Work Piece
Can Be Any Commercial
Metal
Gas Cup
Either Ceramic,
High-lmpact or
Water Cooled
Metal
Inert Gas
Shields Electrode
and Weld Puddle
Tungsten Electrode
Non-Consumable
Art # A-09658_AC
Figure 5-4: TIG Welding Application Shot
Tungsten Electrode Current Ranges
Electrode Diameter
DC Current (Amps)
0.040” (1.0mm)
30-60
1/16” (1.6mm)
60-115
3/32” (2.4mm)
100-165
1/8” (3.2mm)
135-200
5/32” (4.0mm)
190-280
3/16” (4.8mm)
250-340
Table 5-1: Current Ranges for Various Tungsten Electrode Sizes
Guide for Selecting Filler Wire Diameter
Filler Wire Diameter DC Current Range (Amps)
1/16” (1.6mm)
20-90
3/32” (2.4mm)
65-115
1/8” (3.2mm)
100-165
3/16” (4.8mm)
200-350
Table 5-2: Filler Wire Selection Guide
NOTE
The operator should use the welding current range values as a guide only, then finally adjust the
current setting to suit the application.
Summary of Contents for WELDSKILL 200HF
Page 22: ...OPERATING MANUAL 200HF INSTALLATION 3 4 Manual 0 5406 This Page Intentionally Blank ...
Page 28: ...OPERATING MANUAL 200HF OPERATION 4 6 Manual 0 5406 This Page Intentionally Blank ...
Page 38: ...OPERATING MANUAL 200HF SERVICE 5 10 Manual 0 5406 This Page Intentionally Blank ...
Page 56: ...KEY SPARE PARTS 8 2 Manual 0 5406 OPERATING MANUAL 200HF This Page Intentionally Blank ...
Page 59: ...OPERATING MANUAL 200HF This Page Intentionally Blank ...