
PROBLEMS/SERVICE
TRANSMIG 2RT
Manual 0-5196
5-1
PROBLEMS AND ROUTINE SERVICE
SECTION 5: ROUTINE SERVICE REQUIREMENTS
5.01 Cleaning the Welding Power Source
Warning!
Disconnect input power before maintaining.
Each Use
Visual check of
regulator and pressure
Visual check of torch
Consumable parts
Weekly
Visually inspect the torch
body and consumables
Visually inspect the
cables and leads.
Replace as needed
3 Months
Clean
exterior
of wirefeeder
6 Months
Replace all
broken parts
Bring the unit to an authorized
CIGWELD Service Provider
to remove any accumulated dirt
and dust from the interior.
This may need to be done more
frequently under exceptionally
dirty conditions.
Maintain more often if used under severe conditions
Art # A-10472
Figure 5-1 Routine Cleaning