background image

HOT AIR STATION CIF 852-A++ 

 

Ed 1102 

 

CIF 

 

Page 19 sur 24

 

NOTE: 

The life expectancy of a heating element is 1 year under  normal operating 

conditions. 
 

 

 

1

 

3

 

4

 

Summary of Contents for 852-A++

Page 1: ...V700044 INSTRUCTION NOTICE This document contains manufacturer s information which is protected by copyright All rights reserved This document cannot be copied reproduced or translated without written...

Page 2: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 2 sur 24...

Page 3: ...soci t C I F 92220 BAGNEUX France certifie que le produit r pond bien aux directives de la Communaut Economique Europ enne GB Manufacturer declaration C I F company 92220 BAGNEUX France herewith decl...

Page 4: ...aration 8 4 2 Needed material 8 4 3 Risks evaluation 8 4 4 Assembly of the unit 9 5 START UP 11 6 PRECAUTION 16 6 1 Advice 16 7 STAFF PROTECTION 16 7 1 Solder paste and solder wire 16 7 2 Filtration a...

Page 5: ...h digital display Environment friendly repairing system that integrates hot air gun and vacuum pen to pick up components Intelligent error reporting mechanism Detects and informs the personnel for pro...

Page 6: ...pper Power Cord 1 2 Characteristics Power Input 220V Main Station Dimensions 188 w x 127 h x 244 d mm Weight 3 8 Kg HOT AIR Power Consumption 550W Temperature Range 100 C 480 C Heating Element Metal H...

Page 7: ...the tool carrier is very hot This label is sticked on the unit ADVICE Sitting position no special installation needed Only use the unit in a well ventilated area The use without precaution can cause...

Page 8: ...x cleaner 400 ml spray 1 syringe of gel flux for repair 1 set of 50 polyethylene needles diameter 0 4 mm 10 SMD boxes to store components 1 special SMT heating tweezers 1 roll of solder wire 250 grs d...

Page 9: ...h this kind of waste Do not mix the waste 4 4 Assembly of the unit Unpack the unit and assemble the accessories Connect the iron to the unit screwing the connector Caution The switch must be on OFF or...

Page 10: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 10 sur 24 Suction pen receptacle...

Page 11: ...used to reconfigure temperature and airflow level settings Once pressed the system will temporarily switch to stand by mode then start the device using default temperature and airflow level values of...

Page 12: ...t name The temperature heat and air level panel will both display OFF afterwards 2 Start the hot air gun by selecting Reworking from the Hot Air Gun switch F 3 The system will operate at 100 C tempera...

Page 13: ...rn OFF the device by using the power switch 12 Unplug the unit from the power source RECOMMENDATION When adjusting the temperature it is strongly advised to increase the airflow level first in order t...

Page 14: ...rature to bring down temperature to 90 C The panel will then display the following after reaching the safe temperature level and to indicate that the device is now in sleep mode NOTES Time is configur...

Page 15: ...hile the device is adjusting the actual temperature The control panel will then display Axxx to indicate the actual temperature Note that actual temperature may vary for 5 of the defined value This is...

Page 16: ...hands after each handling Put the rejects or dust remains in a container especially dedicated for that use 7 2 Filtration aims Gases and fumes produced during the different manufacturing phases are o...

Page 17: ...e connected to a wide range of suction arms for many applications Ex Filter unit FILTRATEC F item code I51 025 Suction arms Conceived to be connected to the Filtratec units they are all ESD safe Diffe...

Page 18: ...3 screws that secure the hot air gun handle The heating element is located in the middle part of the hot air gun 2 Slide off the plastic tube 3 Disconnect the ground wire sleeve 4 The Quartz glass and...

Page 19: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 19 sur 24 NOTE The life expectancy of a heating element is 1 year under normal operating conditions 1 2 3 4...

Page 20: ...few minutes SOLUTION The thermal sensor may be broken and needs to be replaced PROBLEM 3 ACTUAL AIR TEMPERATURE IS NOT INCREASING Description Actual temperature reading is not increasing or decreasing...

Page 21: ...he device will also reset ail previously defined configurations PROBLEM 6 THE UNIT IS VIBRATING TOO MUCH Check if the 4 screws that hold the pump in place are properly and tightly connected Unplug the...

Page 22: ...Reset button on the device Note that resetting the device will also reset aIl previously defined configurations OTHER PROBLEMS NOT MENTIONED Contact the vendor 9 Nomenclature scheme Reference Descrip...

Page 23: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 23 sur 24...

Page 24: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 24 sur 24 WWW CIF FR...