About this Document
xi
3916 Service Delivery Switch
Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright
©
2013-2015 Ciena
®
Corporation
July 2015
Page 1: ...ch Hardware Installation and Start up Manual 3916 AC Standard 170 3916 900 3916 DC Standard 170 3916 901 3916 Dual AC Standard 170 3916 902 3916 AC Mini 170 3916 904 3916 Dual AC Mini 170 3916 906 Wha...
Page 2: ...is also protected by copyright laws of the United States of America and other countries It may not be reproduced or distributed in any form by any means altered in any fashion or stored in a data base...
Page 3: ...t Ciena to audit the use of the Software at such times as may be mutually agreed upon to ensure compliance with this Agreement 3 U S Government Use The Software is provided to the Government only with...
Page 4: ...CH DATA OR PROGRAMS EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES IN ADVANCE 7 General Ciena may assign this Agreement to any Ciena affiliate or to a purchaser of the intellectual property right...
Page 5: ...ivers Reference 009 2011 602 Orderable part number information removed For ordering assistance please contact your Ciena representative October 2012 Revision B Standard Change title of document Update...
Page 6: ...2015 Ciena Corporation July 2015 Minor update to procedure Logging in through the Serial Console Port on page 3 7 Updated Managing Licenses on page 3 4 July 2015 Revision E Standard Updated Overview o...
Page 7: ...sceivers 2 10 Cable Installation and Guidelines 2 11 Connecting Cables to the 3916 2 12 Fiber Optic Cables 2 12 Ethernet Cables 2 12 Initial Configuration 2 13 List of procedures 2 1 To Install 3916 i...
Page 8: ...ough the Serial Console Port 3 2 Console Cable 3 2 Creating a New User Account 3 3 Deleting a User Account 3 4 Managing Licenses 3 4 Configuring the Remote Management Interface 3 4 Accessing the CLI U...
Page 9: ...901 with integrated front fixed DC power supply in the standard chassis size 3916 AC Mini 170 3916 904 with integrated front fixed AC power supply in the mini chassis size 3916 Dual AC Mini 170 3916...
Page 10: ...ault and Performance 39XX 51XX MIB Reference 39XX 51XX System Event Reference Packet Networking Glossary 009 3299 026 Packet Networking Transceivers Reference 009 2011 602 Document Ordering Informatio...
Page 11: ...About this Document xi 3916 Service Delivery Switch Hardware Installation and Start up Manual 009 3226 001 Standard Revision E Copyright 2013 2015 Ciena Corporation July 2015...
Page 12: ...xii About this Document 3916 Service Delivery Switch Hardware Installation and Start up Manual 009 3226 001 Standard Revision E Copyright 2013 2015 Ciena Corporation July 2015...
Page 13: ...the following items differ between systems Chassis size both standard and mini chassis sizes are available The dimensions are as follows Standard Chassis dimensions 13 1 inches x 7 9 inches x 1 75 inc...
Page 14: ...r or multiple providers The SDS devices incorporate advanced QoS capabilities flexibility through pluggable optics superior multicast control manageability and a small form factor chassis to present t...
Page 15: ...Copper SFPs installed in these ports support 1G UNI 2 10 100 1000 Mbps combo RJ 45 SFP ports The SFPs support both 100 Mbps and 1000 Mbps speeds These are ports 1 and 2 The combo ports have both a cop...
Page 16: ...t up Manual 009 3226 001 Standard Revision E Copyright 2013 2015 Ciena Corporation July 2015 Figure 1 1 View of the 3916 Standard Chassis Figure 1 2 View of the 3916 Mini Chassis 3916 AC Standard 3916...
Page 17: ...e 3916 can also be deployed in a central office environment The 3916 can be mounted on a wall desk or rack When rack mounted the unit requires 1 RU of space This chapter provides installation instruct...
Page 18: ...however the modules or transceivers must be returned to Ciena for service or replacement WARNING Before working on equipment that is connected to power lines remove jewelry including rings necklaces a...
Page 19: ...NG The 3916 AC relies on the AC power cord for the safety ground The outlet providing power to the 3916 must meet the local and national Safety codes The 3916 DC relies on the DC Input connector GND c...
Page 20: ...t your sales representative Note Mounting brackets for 23 inch racks are also available If they are required for your installation you need to order these brackets separately You will also need to ord...
Page 21: ...or other vertical surface The wall mount bracket does not contain any cable management features See Installing the Mounting Brackets in a Wall Mount Installation on page 2 21 for more information Note...
Page 22: ...Common Bonding Network CBN The supplemental ground connection is required on 3916 DC Standard installations The supplemental ground connection is optional on 3916 AC Standard and 3916 Dual AC Standar...
Page 23: ...to the left It is not appropriate to dress the power cord to the right across the front of the 3916 chassis Installing Power to a 3916 AC System Four 3916 systems with AC power exist 3916 AC Standard...
Page 24: ...he power cord See Installing an AC Power Cable in a Mini Chassis system on page 2 32 for a procedure Ciena offers the following AC power cables for the 3916 AC Power Cord IEC C13 Europe AC Power Cord...
Page 25: ...ith the terminal block of the power supply Table 2 1 contains a summary of the recommended locking fork terminal lugs See Installing a DC Power Cable on page 2 34 for a procedure Table 2 1 3916 DC Lug...
Page 26: ...t swappable A reboot is not required after the optics are installed the 3916 will discover the optics automatically Figure 2 2 shows a typical pluggable optic module and its parts Figure 2 2 Pluggable...
Page 27: ...ficult to isolate later When using shielded cables ensure that the cable is terminated to Ground at both ends If it is necessary to run cables across the floor cover the cables with cable protectors t...
Page 28: ...need to know the specification of the optic to select the appropriate cable Ethernet Cables There are two types of ports on the 3916 that have RJ 45 jacks Console Port 10 100 1000 Mbps ports these co...
Page 29: ...3 1 for more information Note If the device has not been assigned an IP address either manually or through a DHCP server other than the default IP address communication can only take place through th...
Page 30: ...g brackets on both sides of the chassis as instructed in Installing the Mounting Brackets for a 19 inch Frame Installation on page 2 18 3 Mount the chassis using one of the following procedures Mounti...
Page 31: ...allation and Start up Manual 009 3226 001 Standard Revision E Copyright 2013 2015 Ciena Corporation July 2015 7 Install faceplate cabling for the UNI and NNI connections See Cable Installation and Gui...
Page 32: ...ation on page 2 21 3 Mount the chassis using one of the following procedures Mounting the Chassis and Installing Supplemental Ground in a Wall Mount Installation on page 2 25 Mounting the Chassis Supp...
Page 33: ...er supplied ground lug Using a ratchet crimper crimp the ground lug c The ground lug should be a 2 hole lug 5 8 centers and with hole size for 10 or 1 4 screw d Using a Phillips screwdriver remove the...
Page 34: ...alling Mounting Brackets for a 23 inch Frame Installation Step Action 1 Orient the bracket so that the face of the bracket is flush with the front of the chassis 2 Using a Phillips screwdriver attach...
Page 35: ...unting bracket kits are available as a separately orderable part Standard chassis bracket kits 23 inch standard bracket kit PN 170 0603 904 Mini chassis bracket kits 23 inch mini bracket PN 170 0098 9...
Page 36: ...hole is an upside down T see Figure 2 4 4 Using a Phillips screwdriver attach the bracket to the left side of the chassis using 2 of the provided screws You have installed the mounting brackets on the...
Page 37: ...two installation options available Facing left orient the brackets so that they are flush with the top of the chassis The top of the chassis will be mounted against the wall Facing right orient the br...
Page 38: ...information see Grounding the Chassis on page 2 6 The following procedure explains how to mount the chassis and connect the 3916 to supplemental ground when the 3916 is installed in a frame Step Acti...
Page 39: ...owing If the chassis is already mounted skip to step 8 If the chassis has not yet been mounted position the chassis in the desired installation location and mount it using the installed brackets and c...
Page 40: ...assis and Installing Supplemental Ground in a Frame Installation on page 2 22 for a procedure The following procedure explains how to mount the chassis when the 3916 is installed in a frame Step Actio...
Page 41: ...ing up or down Step Action 1 Position the standard chassis on the wall so that the air outflow and power supply are at the bottom and the air intake is at the top Note For a standard chassis system wh...
Page 42: ...regulations and safety guidelines and the grounding procedures used by your company 10 Using a digital volt ohm meter verify that the DC resistance between the chassis and the supplemental ground sour...
Page 43: ...ower supply are at the bottom and the air intake is at the top Mini chassis airflow is from the faceplate to the back of the chassis Mini chassis systems can be mounted so that the faceplate is facing...
Page 44: ...ight 2013 2015 Ciena Corporation July 2015 4 Reposition the chassis on the wall and use four customer supplied screws to secure the mounting brackets and chassis to the wall You have mounted the 3916...
Page 45: ...stall the cable support brackets Step Action 1 Install the cable support on the mounting bracket using either the inner or outer screw position and one of the longer 8 32 screws provided in the kit On...
Page 46: ...her side of the power receptacle 2 Position the installed power cord retention clip so that it is folded upward See Figure 2 7 Figure 2 7 AC Power Receptacle with installed Power Cord Retention Clip 3...
Page 47: ...AC Standard repeat step 1 to step 5 to install power to the second AC power supply Note In order to provide power redundancy to the system each input power cable should be connected to an independent...
Page 48: ...le on the front of the chassis Note After it is installed the power cord will be dressed to the left It is not appropriate to dress the power cord to the right across the front of the 3916 chassis 2 I...
Page 49: ...Plug the other end of the power cord into a power source The 3916 will turn on 5 If this is a 3916 Dual AC Mini with Dual AC power supplies repeat step 1 to step 5 to install power to the second AC po...
Page 50: ...the 3916 Note After it is installed the power cord will be dressed to the left It is not appropriate to dress the power cord to the right across the front of the 3916 chassis 2 Remove power from the D...
Page 51: ...nal Block Figure 2 10 DC Connections 5 Tighten the set screws with a Phillips screwdriver 6 Using a flat head screwdriver re install the plastic terminal block cover removed in step 3 on page 2 34 See...
Page 52: ...e power cable to the left and use a cable support on the left chassis bracket to help retain the cable This helps relieve the cord weight from the connector and avoid the inadvertent disconnection of...
Page 53: ...he 20 pin connector card rear of the optic is facing the empty optic slot Note If installed upside down the SFP will only insert halfway into the slot Remove the SFP turn it over and reinstall Do not...
Page 54: ...status LEDs Do not look into the laser to verify operation CAUTION This is a Class 1 laser product Only optics that have been qualified by Ciena should be used in this product The list of supported o...
Page 55: ...c for the port 2 Remove any cabling from the optic 3 Press or pull on the ejector lever depending on the type of optic used and gently pull the optic out of the slot You have removed the pluggable opt...
Page 56: ...hol is used as part of the cleaning process use canned compressed air to blow dry the surfaces you have just cleaned 2 Insert the connector into the port on the device until you hear a clicking sound...
Page 57: ...with the initial configuration of the 3916 including the following Logging in through the Serial Console Port Creating a New User Account Deleting a User Account Managing Licenses Configuring the Rem...
Page 58: ...e converted to DB 9 male or female or Cisco pinout with separately purchased Ciena conversion cables There are three adapter cables available Console Serial Adapter RJ 45 EIA to Cisco RJ 45 pinout 6 i...
Page 59: ...e system and gathers information about the configuration and performance of the system A restricted command set protects user accounts in this group from changing the state of the system in a signific...
Page 60: ...It is strongly recommended that you keep a copy of your license keys in a safe place You need to install the license key on the 3916 in order to activate the features associated with the license Mult...
Page 61: ...sessions can be connected at the same time For a procedure see Accessing the CLI using Telnet on page 3 14 Setting the System Host Name The system host name is a string used to uniquely identify the s...
Page 62: ...ion July 2015 Logging Out of the System When you have completed your initial system configuration you can log out of the system and remove the connection to the serial console port Note Before you dis...
Page 63: ...running terminal emulation software to the serial console port using the recommended cable Note The serial console port does not support connectivity to a modem 3 If using a PC launch the terminal em...
Page 64: ...or more information about user create command options refer to the Administration and Security document for the SAOS release running on the system If you are creating a user account in release Then en...
Page 65: ...per echoless password The following sample output for the user show command confirms that the super user account NewSuper was created user show USER ACCOUNT TABLE Username Privilege New2 super NewSupe...
Page 66: ...t 2013 2015 Ciena Corporation July 2015 user create user NewSuper access level super password changeme The following sample output for the user show command confirms that the super user account NewSup...
Page 67: ...ted 2 Delete the account user delete user user For example the following command deletes the user account su user delete user su 3 Display the accounts in the system user show Example output USER ACCO...
Page 68: ...key String 32 module NUMBER 1 3 file FileName server IPHost Example software license install license key W1SSH2D3E4FGH5 2 Display the status of installed licenses on the 3916 software license show Eac...
Page 69: ...erface configuration interface remote set ip IpAddressWithMask vlan Vlan gateway IpAddress Note You can change the IPv4 gateway in the same command line as the IP address to avoid loss of connectivity...
Page 70: ...Procedure 3 6 Accessing the CLI using Telnet Step Action 1 Use a Telnet client to connect to the 3916 Telnet IpAddress 2 At the login prompt enter a valid user name and password Example 3916 00 02 A1...
Page 71: ...na Corporation July 2015 Procedure 3 7 Setting the System Host Name Step Action 1 Set the system host name system set host name newhostname For example to change the system prompt from the default pro...
Page 72: ...ation July 2015 Procedure 3 8 Logging out of the System Note Before you disconnect from the system ensure that you have saved the configuration using the configuration save command Step Action 1 At th...
Page 73: ...tus LEDs Power Status LEDs 10 100 1000 Mbps Port LEDs All interfaces on the 3916 are accessible from the faceplate of the unit With the exception of the Console port all the interfaces have integrated...
Page 74: ...own in Figure 1 1 on page 1 4 Mini chassis status LEDs are located near the center of the faceplate as shown in Figure 1 2 on page 1 4 Figure 4 1 shows the detailed view of the LEDs for both types of...
Page 75: ...o the system is either on or off 3916 DC Standard no power supply LEDs The power to the system is either on or off 3916 Dual AC Standard two power LEDs labeled PSA and PSB See Figure 4 3 3916 AC Mini...
Page 76: ...Corporation July 2015 Figure 4 4 Power Status LEDs 3916 Dual AC Mini Table 4 2 Power Status LEDs LED Indication Description PS A Off No input power present or failure condition detected Green Power is...
Page 77: ...t 1G Copper SFPs installed in ports 3 and 4 support 10 100 1000 Mbps The LEDs are located at the bottom of the SFP connectors and are labeled LNK ACT and SPD See Figure 4 5 and Figure 4 6 The copper 1...
Page 78: ...015 Ciena Corporation July 2015 Table 4 3 100 1000 Mbps Port LEDs LED Indication Description LNK ACT Left LED Off The port is not operational Green Indicates a valid network connection Blinking Green...
Page 79: ...ation of the 3916 Reset Button There are two different types of resets available Quick reset which is accomplished by depressing the reset button for less than three seconds A quick reset reboots the...
Page 80: ...5 2 Reset Button 3916 Service Delivery Switch Hardware Installation and Start up Manual 009 3226 001 Standard Revision E Copyright 2013 2015 Ciena Corporation July 2015...
Page 81: ...Table 6 1 Specifications Feature Specification Power Rating AC System Single or Dual Power Input 100 240 VAC 50 60 Hz 2 Amps DC System Single Power Input 24 VDC or 48 VDC 2 Amps max Power Consumption...
Page 82: ...4 3 cm H x 27 6 cm W x 17 2 cm D 1 71 in H x 10 85 in W x 6 78 in D Rack Unit Height 1 RU Weight system and SFPs 3916 AC Standard 3916 DC Standard 3916 Dual AC Standard 3916 AC Mini 3916 Dual AC Mini...
Page 83: ...l declarations for 3916 Table 7 1 Regulatory Approval Declarations Issue Approval Declaration Agency Marks CE Europe C Tick Australia New Zealand NRTL Listed VCCI Japan Emissions CISPR 22 2006 Austral...
Page 84: ...tandards requirements based on the following directives 2004 108 EC EMC Directive 2006 95 EC Low Voltage Directive Note Shielded cables are required to meet Class B Some of the supported optics do not...
Page 85: ...n the user is encouraged to try to correct the interference using the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Move the equipment away from...
Page 86: ...7 4 Regulatory Compliance 3916 Service Delivery Switch Hardware Installation and Start up Manual 009 3226 001 Standard Revision E Copyright 2013 2015 Ciena Corporation July 2015...
Page 87: ......
Page 88: ...pyright 2013 2015 Ciena Corporation All rights reserved Publication 009 3226 001 Document status Standard Revision E Document release date July 2015 CONTACT CIENA For additional information office loc...