background image

    |  

13

Chapter 3 – settInGs & fIrst start 

3.8 PC-Connection

To analyze the data recorded by the CM 9.3 A (+) you require the program “

CicloAgent pro

” which can be 

downloaded from our website “

www.CicloSport.com/cm93a

”. Download the file and start the installa-

tion process. 
Once you have installed the software, plug the USb dongle into a free USb port on your PC or Mac. Take the 
CM 9.3 A (+) and press the middle button until the menu appears. Press the left or right button until the 
menu item PC-LINk is displayed. Press the middle button and the display reeds   LINk. To start the transfer 
process, press the left and right buttons simultaneously. The CM 9.3 A (+) is now looking for the USb dongle. 
When connected, “

Linked PC

” will be displayed

The CicloAgent pro will guide you through the download process.

3.9 Others / SET MISC 

3.9.1 Power-saving mode.   

It is recommended to put the CM 9.3 A in power saving mode to conserve battery life.
If you want to put the computer into the power saving mode, press the left or right button in the main menu 
until the lower display shows 

SET MISC

 is displayed, press the center button.

Power down is activated by pressing the left and the right button simultaneously. Pressing the left button 
brings you to 

3.9.2

The CM 9.3A (+) automatically enters a low power mode after approximately 6 minutes with-
out signals received or buttons pressed.

3.9.2 Reset all values  

Pressing the left button in the Power down menu brings you to the totals reset. Press the middle button to 
reset all daily and all total values.
If you want to delete only the daily values without starting a recording, press all three keys simultaneously  
for 5 seconds.

3.9.3 Recording interval   

You can change the recording interval with the right button:

Intervall

Max. recording time

  1 Seconds

    2 Hours

  5 Seconds

  10 Hours

10 Seconds

  20 Hours

30 Seconds

  60 Hours

60 Seconds

120 Hours

The CM9.3 A will overwrite older data if the memory is full without notice. When the current recording has 
overwritten all older files and filled the entire memory of the CM 9.3a, the recording will be stopped and 

MEM F

” will be displayed 

Summary of Contents for MASTER CM9.3A

Page 1: ...Inhalt 1 Wireless cycle computer using digital transmission BlueEye III including altimetry and PC Analysis Manual 20140214...

Page 2: ...ncluding altimetry and PC Analysis ANT CM 9 3 A white black Art No 10104900 Wireless cycle computer using digital transmission including altimetry heart rate monitor cadence and PC analysis ANT D D A...

Page 3: ...0 3 5 1 Altitude 10 3 5 2 Home altitude 10 3 5 3 Unit of measurement altitude 10 3 5 4 Temperature 10 Page 3 6 Heart rate 10 3 6 1 Heart rate 10 3 6 2 Fitness level 11 3 6 3 Sex 11 3 6 4 Weight 11 3 6...

Page 4: ...ased separately to upgrade your CM 9 3A To activate the related functions go to Chapter 3 1 3 Included accessories Spoke magnet Handlebar bracket USB Dongle Speed sensor Cadence sensor Cadence magnet...

Page 5: ...Upper display control Time riding time heart rate Altitude daily distance Power in watt 2 4 2 Lower display control Functions in bold are main functions Functions with need to be activated in the menu...

Page 6: ...On Off Home altitude Unit m ft Unit C F SET Bike 1 2 Symbol RAD Day Dst Tot Dst Wheel Bike Kg Unit km mi Cad On Off Power On Off PoeAvg LR Pwr Off On SET clock Time Year Month Day Clock 24 12 SET HF...

Page 7: ...ized Section 3 7 1 tighten the cable ties The ends of the cable ties can be cut off with a clipper or scissors 3 1 4 Spoke magnet Attach the magnet to a spoke on the opposing of the transmitter Please...

Page 8: ...stance Now Tot Dst is shown in the display and you can set the overall miles kilometer Set with the middle and right button store with left button 3 3 3 Wheel Now you can set the wheel circumference t...

Page 9: ...ate values Whenever the calculated power is shown in the lower display the value is shown with a P for power Measured power To display measured power you need an ANT compatible power sensor and initia...

Page 10: ...r bike When you start a recording the computer adjusts to this value If you start from a different location switch the home level to OFF If you want to set a home altitude switch Home to ON Set with t...

Page 11: ...apter 4 6 If you don t need CICLOInZone just push the left button to skip the calculation In order to obtain an exact calculation of one s personal CICLOInZone it is necessary to insert the personal f...

Page 12: ...ss the left and right button simultaneously to start the sensor search As soon as the sensor is found the CM 9 3 A will display connected in the bottom line If no sensor of the selected type can be fo...

Page 13: ...nto the power saving mode press the left or right button in the main menu until the lower display shows SET MISC is displayed press the center button Power down is activated by pressing the left and t...

Page 14: ...between the bike modes before entering the menu to change the settings for the current bike 4 3 Light The backlight is activated by pressing the left button for 4 seconds The light stays on for 5 seco...

Page 15: ...ow do you find the right intensity of effort during training CICLOInZone is the optimum training ZONE for effort resistance and weight loss What does CICLOInZone do It calculates the optimum training...

Page 16: ...ttery 5 3 2 No Speed Cadence HR Power The sensor was not initialized correctly Under 3 7 1 Check the sensors if they are mounted CORRECTLY see 3 1 Check the distance between the transmitter and the ma...

Page 17: ...ate and all accessories and with sufficient postage to Fa Ciclosport Service Einsteinstr 39a 82152 Martinsried Planegg Germany E Mail ciclo service ciclosport de Before returning the product please re...

Page 18: ...t be treated as household waste In stead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of cor...

Reviews: