3 search results are possible:
Case 1
No search results. The heat pump has not been identified by the control terminal:
- Repeat the heat pump stimulation procedure
- Press the button
- Restart the heat pump pairing sequence by moving closer to it.
Case 2
The search locates the heat pump's radio signal:
- Turn the button to select CONFIRM
- Press the button to end the sequence: LED D30 should flash every 0.5 seconds until the
button is pressed to confirm.
If pairing is successful, the message "pairing successful" appears on the
screen for 3 seconds, then the terminal returns to the Heat pump pairing menu:
- Heat pump pairing is complete
- The Heating
, Operating mode
and Information menus appear in the main menu
If this is not the case, pairing has not been successful and the message
"error: pairing failed" appears on the screen for 3 seconds:
- Repeat the heat pump stimulation procedure
- Press the button
- Restart the heat pump pairing sequence, strictly adhering to the powering up and powering
off times.
Case 3
The search finds several radio signals from different heat pumps:
- Make sure the heat pump stimulation procedure is only performed on the machine
concerned
- Repeat the heat pump stimulation procedure
- Press the button
- Restart the heat pump pairing sequence
If pairing is successful (scenario 2), the Add function disappears from the screen and 3 new
functions appear: Check/Delete/Replace.
To perform the outdoor sensor pairing procedure, select Back from the drop-down list.
Select "CONFIRM" by turning the
button then confirm
CLIC
Heat pump pairing
d
eLeTe
B
ack
c
Heck
Heat pump pairing
H
eaT
pump
found
idenTificaTion
in
progreSS
S
eTTing
canceL
Heat pump pairing
p
airing
SucceSSfuL
Heat pump pairing
error
p
airing
faiLed
Heat pump pairing
H
eaT
pump
noT
found
Heat pump pairing
SeveraL
HeaT
pumpS
found
Back
replace