SCHEDA DI COLLAUDO – TEST SHEET
PYTHAGORAS RX MW
NUMERO DI SERIE
SERIAL NUMBER:
Cliente/Customer
Indirizzo/Address
Barriera /Barrier N°
(*) misura che può essere effettuata anche con lo strumento STC 95
(*) It is possible to make the measure also by the STC 95
OSSERVAZIONI DELL’INSTALLATORE – INSTALLER COMMENTS
Data installazione/Installation date
Firma Installatore/Installer Signature
VALORI MISURATI SUL RICEVITORE – MEASURED VALUES ON THE RECEIVER
VALORI MISURATI
MEASURED VALUES
MISURE
MEASUREMENTS
VALORI TIPICI
STANDARD
VALUES
INSTALLAZIONE
INSTALLATION
MANUTENZIONE
MAINTENANCE
1
TENSIONE DI ALIMENTAZIONE, MISURATA TRA I
PIN 1-2 DI MS3, CON BATTERIA SCOLLEGATA. (*)
SUPPLY VOLTAGE, MEASURED BETWEEN PINS
1-2 OF MS3 WITH BATTERY DISCONNECTED. (*)
13,8 VDC
±
10%
2
TENSIONE DI ALIMENTAZIONE INTERNA,
MISURATA TRA IL PIN 12 DI J3 E GND. (*)
INSIDE SUPPLY VOLTAGE MEASURED BETWEEN
PIN 12 OF J3 AND GND. (*)
5 VDC
±
10%
3
TENSIONE DI RAG, MISURATA TRA IL PIN 14 DI J3
E GND. (*)
AGC VOLTAGE MEASURED BETWEEN PIN 14 OF
J3 AND GND. (*)
2,5
÷
6 VDC
4
VERIFICA SEGNALE RIVELATO, MISURATA CON
LO STRUMENTO STC 95.
SIGNAL DETECTED VOLTAGE MEASURED BY
STC 95.
6 VDC
±
10%
STABILE
STEADY
5
CANALE DI MODULAZIONE UTILIZZATO
MODULATION CHANNEL USED
-
□
Ch 0
□
Ch 8
□
Ch 1
□
Ch 9
□
Ch 2
□
Ch A
□
Ch 3
□
Ch B
□
Ch 4
□
Ch C
□
Ch 5
□
Ch D
□
Ch 6
□
Ch E
□
Ch 7
□
Ch F
□
Ch 0
□
Ch 8
□
Ch 1
□
Ch 9
□
Ch 2
□
Ch A
□
Ch 3
□
Ch B
□
Ch 4
□
Ch C
□
Ch 5
□
Ch D
□
Ch 6
□
Ch E
□
Ch 7
□
Ch F
TAGLIARE
QUI
/CUT
HERE