CIAS Elettronica S.r.l.
Ed.
.2.4
Installation Manual
Pag. 35 of 36
Murena/Murena-Plus24
6 CHARCTERISTICS
6.1 Technical Characteristics
This table lists the technical characteristics of the
Murena
detector
.
TECHNICAL CHARACTERISTICS
Min
Nom
Max
Note
Operating Frequency
9.47 GHz 10.525 GHz 10.58 GHz
Maximum Power
-
20 mW
EIRP
-
Modulation
-
-
-
on/off
Duty-cycle
-
1/24
-
Range
1 m
-
24 m
Current consumption normal with leds ( mA -- ):
72
-
135
Current consumption in alarm with leds ( mA -- ):
70
-
132
Current consumption normal with serial ( mA -- ):
75
-
140
Intrusion Alarm Contact (Static Relay)
-
-
100mA
C-NC
Tamper Alarm Contact (Static Relay)
-
-
100mA
C-NC
Fault Alarm Contact (Static Relay)
100mA
C-NC
Red Led for Intrusion Alarm
-
-
off
Red Led for Tamper Alarm
-
-
off
Red Led for Fault Alarm
-
-
off
Six Red led to display various functions
off
Function Selectors
On board
Range Control 24 steps of 1m each
Onboard/SW
Target Size Control
Onboard/SW
Pre-alarm threshold control
Onboard/SW
Alarm threshold control
Onboard/SW
Masking threshold control
Onboard/SW
Weight
-
500 g
-
Dimensions
-
-
175 x 175
mm
Complete depth with mount
-
-
115 mm
Operating Temperature
-25 °C
-
+55 °C
Design Level:
3°
Environmental Protection:
IP55