background image

                                                                                                                                                                                   

 

 

Definition of Keypad Operation 

Number 

of N 

Value

 

Control Object 

Call No. N Preset Point 

Set No. N Preset Point 

51 

Start Scan (low Speed) 

Start Patrol 

52 

Start Scan (middle Speed) 

Set Start Position of Scan 

53 

Supplementary Control of 

dome 

Start Scan (high Speed) 

Set End Position of Scan 

54 

Power Supply of Camera 

Power Supply On 

Power Supply Off 

55 

BLC 

On Off 

56 

Zero Illuminance 

On 

Off 

57 

Screen Display * 

On 

Off 

58 

D-Zoom On 

Off 

59 

Focus Automatic 

Manual 

60 

Iris Automatic 

Manual 

61 

Automatic Manual 

62 

Interior Exterior 

63 

Mode of White Balance * 

ATW One 

Push 

WB 

64  

 

 

Notes: 

1.    Those Items with “*” have memory function even the dome is switched off. 
2.    For those cameras with “menu”, you can use “Screen Display ON” to control the 

Menu ON/OFF, and use “Screen Display OFF” to control Screen Display 
ON/OFF. 

3.    For those cameras which have no “Zero Illuminance” or the function of “Zero 

Illuminance” is automatically switched without control, then above “Zero 
Illuminance” is invalid. 

4.    Notes to “Patrol” Function of the dome camera: 

  Automatically scan from no.1 to no.16 preset points one by one. If some 

points do not have been preset or are cleared out after presetting, they will be 
bypassed when patrol is carrying out. 

    The dwelling time between to preset points is 4 seconds. 

    The “Patrol” function of the dome camera can be carried out by presetting 

no.51 position. 

5.    Notes to “Scan(auto pan)” Function of the dome camera: 
       

    The dome camera makes automatic scan between two specified positions. 

       

    The speeds of scan are divided into three levels. You can call no. 51, 52 and 

53 preset position to start scan at speed of 1.5°/ sec, 5°/ sec and    10°/ sec 
separately. 

    The dwelling time between the “Start Point” and “End Point” of scan is 3 

seconds. 

6.  All notes mentioned above are supplementary descriptions under high speed. All original 

operations of the control system are unchanged.

 

z

 

Settings of Communication Baud Rate of the dome Camera   

Summary of Contents for TVCD606

Page 1: ...Installation and Operation Manual for TVCD606 ...

Page 2: ...2 Please read the operation manual carefully before installing and using this unit ...

Page 3: ...should keep enough distance with high voltage equipments and cables when they are in transmission Precautions for anti lightning and anti surging should be taken if necessary 6 The product should be indoor installed and operated to avoid rain and moisture Do not use it in wet places If outdoor installation is needed the closed protect cover should be used and it is absolutely prohibited to use it ...

Page 4: ...g dome P T a Turning 360º horizontally and continuously with unlimited positions PAN speed range 0 15rad s constant speed dome PAN 15rad s turning 0 90º vertically with a speed 0 15rad s constant speed dome TILT 15rad s b Running stably at low speed with super lower noise Pictures have no shaking c the location precision up to 0 2 3 High Intelligent Degree a Support the dome camera to scan horizon...

Page 5: ...ected Take care that on RS 485 Bus only one farthest spherical camera has the terminal resistor connected while other devices should have their terminal resistors opened z Settings of Addresses of dome Cameras States of Coding Switches Dome Addres s DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8 DIP 9 DIP 1 0 1 ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF OFF OFF 3 ON O...

Page 6: ...s the protocol has been done Selection of Protocols Normal Baud Rate Type of Protocols DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 Integrated Protocol Minking A01 OFF OFF OFF OFF ON OFF Minking B01 ON OFF OFF OFF OFF ON Santachi OFF ON OFF OFF OFF ON PELCO D ON ON OFF OFF OFF OFF PELCO P 4800 ON OFF PELCO P 9600 OFF OFF ON OFF OFF ON PANASONIC ON OFF ON OFF OFF ON Longcomity OFF ON ON OFF OFF ON HUNDA600 ...

Page 7: ...the function of Zero Illuminance is automatically switched without control then above Zero Illuminance is invalid 4 Notes to Patrol Function of the dome camera Automatically scan from no 1 to no 16 preset points one by one If some points do not have been preset or are cleared out after presetting they will be bypassed when patrol is carrying out The dwelling time between to preset points is 4 seco...

Page 8: ...ply which is provided with the dome camera Red DC12V Black GND Orange RS485 Yellow RS485 VIDEO 4 Take out the mounting base from the spherical camera thread the connecting wire from behind through the central hole of the base Fix the base by three screws on the ceiling as per the drawing and connect the wire with the ball Aim the latch in the ball with the notch on the base as per the drawing and ...

Page 9: ...Power Supply DC12V 10 1 2A Power Consumption 12VA Weight 2Kg Mounting Style Ceiling or ceiling hanging style Relative humidity 10 75 under no condensing Specifications Operation Temperature 0 40 Scan System 15 625KHz H 50Hz V Horizontal Resolution 480 TV lines Signal Noise ratio Larger than 48 db Electronic Shutter 1 3 1 10000 seconds Camera Function Lowest Temperature 1Lux AGC ON Lens Data Zoomin...

Page 10: ...of VF circuit Correct Bad connection of VF circuit Remove Normal self inspection but no images Camera damaged Replace Wrong connection of control signal wire Correct Mismatched address of spherical camera Reselect Successful self inspection but out of control Mismatched protocol Adjust protocol to match with the controller and switch on again Bad connection of VF circuit Remove Images unstable Ins...