27
Setup
OPEN
IN PAUSE
CLOSING
The reclosing is stopped and at the end of the
pause, it restores other 5 sec. up to the reset
The gate stops and it opens immediately.
Stops operation and the gate opens immediately
IN STOP
Restarts the operating procedure before the
STOP (closing or opening)
The pulses A and B will be ignored.
The opening or closing operation are locked
GATE
STATUS
PULSE A
PULSE B
STOP
PHOTOCELL 1 PHOTOCELL 2
CLOSE
OPENING
PARTIAL
OPEN
IN PAUSE
CLOSING
3.1.1
AUTOMATIC FOR PARKS operating
(SW1=OFF - SW2=OFF)
One pulse allows : opening , pause , automatic closing .
During the opening operation, other pulses will be ignored. During the closing operation,
possible pulses stop and reverse the movement of gate immediately.
A contact closed on PULSE A ( Clock function ) allows to open the gate up to the setted pause
and it be open up to the opening of the contact.
3.1.2 AUTOMATIC
operating
( SW1=ON - SW2=OFF)
One pulse allows :opening, pause, automatic closing.
During opening and closing procedures, every pulse stops and reverse the movement of the
gate immediately.
During the pause, a pulse recloses the gate immediately.
Total Opening and
reclosing after the time
of pause
No effect
if the opening
is started by the
PULSE A
No Effect
Stops operation
and switches to
STOP mode
No Effect
The reclosing is stopped and at the end of the
pause, it restores other 5 sec. up to the reset
The reclosing is stopped and at the end of the
pause, it restores other 5 sec. up to the reset
A total opening is possible.
The closing is stopped and the gate opens
again immediately
Stops operation and the gate opens immediately
Restarts the operating procedure before the
STOP (closing or opening)
The pulses A and B will be ignored.
The opening or closing operation are locked
Partial Opening and
closing operation after
the time of pause
Total Opening
if the
opening is started by
the PULSE B
GATE
STATUS
PULSE A
PULSE B
STOP
CLOSE
OPENING
Total Opening and
reclosing after the time
of pause
See SWITCH 3 pages 9 and 10
Stops operation
and switches to
STOP mode
No effect
Partial Opening and
reclosing after the time
of pause
The gate stops and it recloses immediately.
The gate recloses immediately
PHOTOCELL 1 PHOTOCELL 2
TOTAL
OPEN
IN PAUSE
Total Opening
The reclosing is stopped
and at the end of the
pause it restores other 5
sec. up to the reset
The reclosing is stopped and at the end of the
pause, it restores other 5 sec. up to the reset
Disables A and B pulses
and disable opening
Disables A and B pulses
and disable opening
ON
ON
See SWITCH 3 pages 9 and 10
IN STOP
26
PCM100 / PCM130 - User Manual
3
Setup
3.1
Operating mode
The operating mode and the various options are settable by the switches 1, 2 and 3 of the dip-
switch present on the board ( a page 21 and 22). The switch 4 can set the installed photocell model
(see previous page). Here's a summary of all options:
To learn about operating logics see next paragraph.
ATTENTION: The DIP- SWITCH setting up has to be made with central unit switched off.
15
Automatic for Park
operating
OFF OFF
Automatic operating
ON
OFF
Step by step
with automatic closing
OFF
ON
Step by step
with STOP
ON
ON
Locking enabled
Locking disabled
Switch 1 and 2:
Operating
Switch 3:
Opening locking
on
photocells
interruption
SWITCH 4:
Tipo di
fotocellula
installata
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
FX30 (autodiagnosis)
FX40 - FX55
2.4.4
Digital photocells with autodiagnostic(FX40D,FX55D) (FX30D)
ON
DIP1
SW4=ON
NOTE: Installing the FX30D it is obligatory to mount two photoelectric cell braces.
Rx 1
( page 7)
4
Rx 2
( page 7)
2
1
2
JM
P1
CH
.A
CH
.B
JM
P1
CH
.A
CH
.B
1
2
JM
P1
CH
.A
CH
.B
1
2
1
2
JM
P1
CH
.A
CH
.B
Tx 1
( pagina 7)
5
Tx 2
( page 7)
3