Installation
1
Introduction
1.1
Central Unit Description
1.2
PCM100 and PCM130 Central Unit for sliding gates operates a geared-motor 230Vac
700VA max, as MS100 or MS200 producted by CIA and geared motor MS200T (380Vac
550W), by an electrical clutch, realized with a microprocessor of last generation. PCM100 and
PCM130 Central Unit are furnished with a sophisticated circuit of auto-diagnosis that controls
costantly the operation of the system and connected devices; in case of troubles, the circuit
stops all central unit operation. The monitoring of peripheral operating connected to the central
unit is displayed by LEDs placed on the circuit. Moreover, PCM100 and PCM130 Central Unit
are furnished also with a electrical brake to guard the stop of geared-motor. In place of the
brake, the slowing down function is activated 3 seconds before the limit stop to avoid
unnecessary impacts during the opening and closing operating.
PCM100 and PMC130 Central Unit are in accordance with EMC 89/336 directives and
73/23 EEC directives.
Features
PCM100 / PCM130 - User Manual
2
Installation
2.1
Board Description (PCM100)
230V~ ±5% 50Hz
700VA
4KW
24V~ ±5% max 0,3A
6VA
11VA
125mA
IP44
IP54
90sec. Max
4 ÷ 60sec.
4 ÷ 130sec.
ABS
-25°C ÷ +55°C
127mm
195m
138mm
250mm
57mm
100mm
0.075Kg
1Kg
!
Control inputs: STOP input; PULSE A: total opening, PULSE B: partial opening (pedestrian passing), photocells, limit stop
Built-in interface for BIRD receiver
Peripheral monitoring by LEDs
Programmable operating modes: Automatic, Semiautomatic, Step-by-step with automatic closing, Step-by-step with STOP
Control inputs: STOP input; PULSE A: total opening, PULSE B: partial opening (pedestrian passing), photocells, limit stop
!
!
!
!
PCM100
PCM130
Power supply voltage
Max power for geared motor
Service output voltage
Max current consumption
Max current supplied on service output
Box protection level
Opening/closing time
Pause time
External box
Operating temperature
Dimensions (W)
Dimensions (H)
Dimensions (D)
Weight
"SLOWING DOWN" function with "BRAKE"
trimmer at minimum
Function "BRAKE" adjustable by trimmer with
exclusion to minimum
Predisposition for security photocells FX30, or others
Regulation trimmer: "BRAKE", "PAUSE",
"CROWD FORCE”
Regolation of “OPENING” and PAUSE by
trimmer
11 - Common
12 - Pulse STOP (NC)
13 - Pulse A (NO)
14 - Pulse B (NO)
15 - NC
16 - Common
17 - NC
18 - 24V~ max 100mA
19 - 24V~ max 100mA
6 - Closing
7 - Common (blu wire)
8 - Opening
GEARED MOTOR
230V~ 700W max
4 - Pole 1
5 - Pole 2
FLASHER 230V~
PHOTOCELLS
(FX30D - FX40D)
9 - Pole 1 (clamp 1 BIRD)
10 - Pole 2 (clamp 2 BIRD)
BIRD ANTENNA
20 -
Limit-stop connector
Limit-stop connector
Voltage fuse (250Vac 3,15A)
Trimmer C: electr. brake / slowing down
Trimmer B: time of pause
LED microprocessor diagnosis
Setup Dip-Switch
LED Button P1
LED Button P2
learn remote
control code
P2: partial opening
P1: total opening
Opening/closing limit stop clamps, to
use when central unit is installed outside motor.
Opening/closing limit stop connector, to
use when central unit is installed inside moto
LED photocell 1 status
LED STOP Status
Photocells and 24 Vac clamps
BIRD and commands clamps
Flasher and motor clamps
230Vac power supply clamps
2.1.1 Connections
(PCM100)
Trimmer A: electronic clutch
1
2
3
4 5
6 7
8
9 10 11 12 13 14 15 16 17 18 19
LED closing limit stop status
LED opening limit stop status
LED photocell 2 status
21
22
23
20
20 - Opening limit-stop
21 - Limit-stop common
22 - Closing limit-stop
LIMIT-STOP
Use this clamps only if central
unit board is installed outside
of the geared-motor.
1 - L1
2 - Ground
3 - N
POWER SUPPLY
230V~ ±10% 50Hz
COMMANDS
NOTE: If it should be necessary to
invert the limit-stop wires, invert the
and
magnets at page 6.
9
10
Use this connector only if central unit
board is installed inside of the geared-
motor.