Page 22
6. Specifications
POWER SUPPLY:
a) 3 x Alkaline D cells giving 2 years operation*
b) 230/240V AC @ 10VA, max. with 8 battery back-up
c) 110/120V AC @ 10VA, with battery back-up
d)
External
10…15V
DC
@
1A
max.
d)
External
3.0...5.5V
DC
@
1A
max.
* Battery life based on power-save mode with 100ms
transducer settling time, interrogated every 15 minutes
HARDWARE I/O:
Digitals:
Inputs:
4 digital / count inputs compatible with external volt free contacts
Energising
voltage:
Supply
voltage
(3.0…5.5V)
when
asleep
5.0V
when
awake
Switching
current:
50mA
wetting
current,
10
A continuous
Maximum
count
rate:
50
pulses/second
Outputs:
Optionally 4 digital volt free contact outputs rated 125VAC/1A/60VA max.
60VDC/1A/30W max. with common return.
Analogues:
Inputs:
2 Analogue inputs (non isolated).
Range:
0…20mA
into
5
or 100mV strain gauge
Accuracy:
1%
Energising voltage V+:
9.5…10.0V @ 40mA max. (only available when awake)
Common
mode
range:
0…V+
Pseudo inputs:
Battery
volts
(0…10V
1%)
RSSI
(0…100%).
Outputs:
Optionally 2 Analogue outputs (non isolated).
Range:
0-10mA
or
0-20mA
@
9V
max.
Accuracy
1%
Summary of Contents for Nano Link IP67
Page 40: ...Page 38...