Chuphotic Venus Smart 1K User Manual Download Page 17

15

7. Specifications                                                                                                                

 

  7.1 Electrical

Model  

 

VNS1050/L 

VNS2000/L 

VNS3000/L

Rating

 

PF 0.8 

1050VA/840W 

2000VA/1600W 

3000VA/2400W

 

 

PF 0.9 

1050VA/945W 

2000VA/1800W 

3000VA/2700W

Input

Output

Battery

Output  

frequency

Inverter overload 

capacity (Utility 

power, 25

o

C)

Transfer time

Normal 

mode

Battery 

mode

Input system 

 

 

Single phase & earth ground

Voltage range 

 

 

(90±5)VAC~ (300±5)VAC

Output system 

 

 

Single phase & earth ground

Batteries voltage 

          36VDC 

         72VDC/96VDC  

96VDC

Rated voltage 

 

 

 

220VAC

Battery quantity 

     3 

     None          6/8           None                8             None

Power factor 

 

 

 

>0.99

Battery Type

Voltage precision 

 

 

 

±1%

Backup Time (25ºC)   

 

Full load≥5min (Standard)

Charge current 

     1A 

      6.5A           1A            5.5A             1A               5.5A

Crest factor 

 

 

 

3:1

1. The output frequency synchronizes with the input frequency when the  

  input frequency is in the range of  45Hz~ 55Hz.

2. The output frequency is 50Hz when the input frequency is not in the  

  range of 45Hz~ 55Hz.

3. Can be set as 60Hz.

100% ± 5% < Load ≤ 105% ± 5% Overload warning only

105% ± 5% < Load < 125% ± 5% 60s transfer to bypass

Load > 125% ± 5%, 30s, Load > 150% 300ms transfer to bypass

               0ms (Normal mode←→ Battery mode)

              <4ms (Normal mode←→Bypass mode)

Sealed maintenance-free lead –acid battery 

 

of battery voltage 12V/7.5AH or 12V/9.4AH 

Power factor 

 

 

 

≥0.99

Voltage range 

              (80±5)VAC~ (286±5)VAC (default: 80VAC~264VAC 

of bypass    

 

              Could be adjusted by software)

* Note1: Output voltage can be set: 200V/208V/220V/230V/240V.

• All specification are subject to change without prior notice.

Summary of Contents for Venus Smart 1K

Page 1: ...HUPHOTIC CO LTD ENERGY WAVE CO LTD CHUPHOTIC ELECTRONICS CO LTD 949 Moo 9 Sumrong Nue Muang Samutprakarn Samutprakarn 10270 Tel 02 186 3011 Fax 02 186 3018 19 Website www chuphotic com E mail ups chup...

Page 2: ...g Inspection 4 3 2 Installation Notes 4 3 3 Cable Connection 4 5 4 Operation LCD model 6 10 4 1 Operation Display Panel 6 4 2 Operation Mode 6 8 4 3 Operating Instructions 9 10 5 Maintenance 10 11 5 1...

Page 3: ...Do not short the positive and negative electrodes of battery Otherwise it may cause electric shock or fire 6 Do not plunge or insert any objects into the air vents and other inlets 7 Do not store or...

Page 4: ...el Remark 1K With a 1A internal charger and 3 build in batteries of 12V 7AH 2K With a 1A internal charger and 6 or 8 build in batteries of 12V 7AH 3K With a 1A internal charger and 8 build in batterie...

Page 5: ...battery through the DC DC converter 5 Bypass It is very important in the UPS system In the event of a UPS fault that will not lead to UPS shutdown the load will be automatically transferred to the byp...

Page 6: ...o wait until the UPS fully dried inside out before proceeding to installation and use Otherwise they may be a risk of electric shock 4 Place the UPS near the utility power source outlet which supplies...

Page 7: ...t on the rear panel of the UPS to complete the connection procedure Note The length of the external battery cable is 1 6 m If users need a longer one please consult the distributor There is a limit to...

Page 8: ...ndicators The LED indicators contains Bypass indicator utility power indicator Inverter indicator Battery indicator The definition of each indicator is the same as LED panel refer to table 4 1 Table 4...

Page 9: ...oads connected to the UPS less than 100 capacity of the UPS 3 If the battery indicator blinks it indicates that no battery is connected to the UPS or battery voltage is too low You should check if bat...

Page 10: ...er another circularly When the battery is fully charged all the level icons are turned on 1 When operating in bypass mode the UPS beeps every 2 minutes If the Function key is pressedfor more than 2 se...

Page 11: ...switch to output page by pressing function button When a warning occurred the fault icon blinks every second and users can switch to the alarm display page shown as the figure 5 6 to check the warning...

Page 12: ...s shown on the front panel and no output is available from the UPS outlets system completely power down 2 Completely power down the UPS from Battery mode Press the OFF button persistently for more tha...

Page 13: ...rature between 15o C and 25o C 3 If the UPS has not been used for a long period charging is recommended at the intervals 3 months 4 Batteries should not be replaced individually 5 Under normal conditi...

Page 14: ...tributor or service center The 8 utility power LED blinks in normal mode Maybe reversed polarity L N of site wiring or disconnect with ground or the voltage between neutral wiring to protective ground...

Page 15: ...or Service center F05 On constantly Beep continuously Internal fault Please contact the distributor or Service center F06 On constantly Beep continuously Internal fault Please contact the distributor...

Page 16: ...every second Battery voltage low The UPS output will be cut off please switch to the backup power A03 Beep once every second UPS power on abnormal Check the battery of the UPS connected properly A05...

Page 17: ...Standard Charge current 1A 6 5A 1A 5 5A 1A 5 5A Crest factor 3 1 1 The output frequency synchronizes with the input frequency when the input frequency is in the range of 45Hz 55Hz 2 The output freque...

Page 18: ...IEC61000 4 4 LEVEL4 Surge IEC61000 4 5 LEVEL4 7 Specifications 7 2 Mechanical Item Normal range Ambient temperature 0 C 45 C Environment humidity 0 90 No condensation Altitude Lower than 1000m no dera...

Page 19: ...odel Intelligent monitor software CD 1 User Manual 1 Serial communication cable 1 UPS 1 Intelligent monitor software CD 1 Long backup time Model User Manual 1 External Battery Cable 1 Serial communica...

Page 20: ......

Page 21: ...Service center please Call 02 1863011 AUTO...