20
It is the smart cleaning function that prevents contamination by automati-
cally cleaning the tank every 15 days, when frequency of use is low.
• It operates same time every 15 days, as it is set the standard time which
is 12 hours later after connection of power.
e.g.) When the power is connected at 2 P.M, it is operated at 2 A.M every
15 days. If users want to change the operation time, turn off the power
at desired time and turn on.
① When smart cleaning function is operating, "ICE FULL/WATER FULL"
LED blinks by turns around 9 minutes and users cannot use the unit at
this time.
② Use the unit when the smart cleaning function is finished and cold
water tank are filled again. (Around 20-40 minutes until water full.)
※
Press "COLD" touch button for 10 seconds to operate smart cleaning
function. Smart cleaning function is released when it is pressed for
10seconds again.
Smart cleaning function
① When the water level in the ambient water tank reaches to specific level, it starts to remove all the
remaining ice on the evaporator. This action is done when power is newly supplied to the unit.
② The compressor and ice making pump operate in order to make cold water.
(The cold water unition process automatically operates according to designated programming.)
• Cold water operation: Cold water is made by process of spraying water to evaporator. Water temperature in
the cold water tank is automatically detected by the sensor, and if it drops below the set temperature, then
the cold water operation will automatically stop.
③ If cold water unition is done, ice making get started in accordance with the process of ice forming and
ice harvesting action.
•Ice forming action: Spray cold water to the evaporator for given time.
•Ice harvesting action: Supply heat to the evaporator to remove ice from the evaporator.
④ When the ice storage is full, the ice level sensor automatically sends the signal to stop ice making
process.
⑤ If ice in the storage is not used for long periods of time, it may melt and small pieces of ice can be
served during ice dispensing.
※TDS(Total Dissolved Solid) of ice may increase slightly according to the environment in which the
ice is made.
•The lower room temperature is, the shorter the ice making process will take and the higher room
temperature is, the longer the ice making process will do.
•Do not install or use the unit in temperatures below 32℉(0℃) or above 104℉(40℃).
Understanding the ice making process and operation
●
Ice making system of the unit starts and operates to make ice automatically according to program
set after power is ON.
Usage
커피얼음정수기_메뉴얼_영문2_T_461_메뉴얼_5170S 14. 9. 22. 오전 10:22 페이지 22