Power Supply Control 
 

If battery power is running low, the buzzer and the red LED will signal five times after 
each keypad entry.  The “ON” button must be pressed before it is possible to open 
the lock, and pressing “ENTER”  to  change  codes  is  blocked.  This  operation  is 
indicated by a single long buzzer and red LED remains lit. 

 

To replace the battery:  
 
If the door is closed, you will need to apply a 9V battery to 
the external power connectors (“+” and “-“ respectively) 
between the handle and the keypad.  
Make sure you observe correct polarity. 
Holding the battery against the contacts enter a valid code 
and open the safe by turning the handle clockwise. 
 
Battery Requirements: 
Model - 6LR61  Voltage - 9V 

Battery Type - ALKALINE 

 

Changing the Battery 
In  order  to  change  the  main  battery  it  is  necessary  to  unscrew  the  cover  in 
the rear of the door and carefully remove this from the unit.   
Carefully  remove  the  plastic  cap  from  the  lock,  take  out  the  discharged 
battery and disconnect it.  
Connect  the  new  battery  to  the  battery  connector  (taking  care  to  observe 
correct polarity), replace the plastic cap and replace the cover on the rear of 
the door. 
 

Attention! 
Having changed the battery, it is strongly recommended that you 
check  the  new  battery  by  opening  and  closing  the  lock  two  or 
three times while the door is opened. Only after that should you 
close the door. 

  

 

 

 

 

Summary of Contents for Professional S2

Page 1: ...USER GUIDE PROFESSIONAL S2 SAFE www chubbsafes com Chubb is owned by Chubb plc and is a registered trademark used under license ELECTRONIC LOCK USER GUIDE...

Page 2: ...and green LED to flash twice The green LED will then flash for a further 7 seconds THE HANDLE MUST BE TURNED WITHIN THIS 7 SECONDS PERIOD otherwise the safe will return to the locked state Entering an...

Page 3: ...xtend the door bolts 2 The safe is now locked Programming Codes 1 Programming the Primary Code Press ON Press ENTER Press 1 Press ENTER Input the valid primary code 1 2 3 4 5 6 initially and press ENT...

Page 4: ...m 6 to 8 figures and press ENTER Re enter the user code and press ENTER Audio and visual signals are the same as for the primary code programming 3 Programming the User Code without the Primary Code P...

Page 5: ...s enter a valid code and open the safe by turning the handle clockwise Battery Requirements Model 6LR61 Voltage 9V Battery Type ALKALINE Changing the Battery In order to change the main battery it is...

Page 6: ...of the time delay period 1 9 minutes e g entering 053 a time delay of 5 minutes followed by 3 minutes in which the safe should be opened Press ENTER the green LED flashes twice Opening the safe with...

Page 7: ...TER buzzer and green LED will operate twice Activation deactivation of the buzzer To turn on or off the sound Press the ON button buzzer will sound and green LED will flash Press the ENTER button buzz...

Page 8: ...f the corner of the safe this will help later when the safe has to be repositioned Remove the safe temporarily Using a 12mm diameter masonry bit and percussion drill create two holes each 90mm deep in...

Reviews: