Programmable AC Source 61501/61502/61503/61504 User’s Manual
8-12
8.6.2.3 SOURCE Sub-system
[SOURce :]
CURRent
:
LIMit
:
DELay
:
INRush
:
STARt
:
INTerval
FREQuency
[: {CW | IMMediate}]
FUNCtion
:
SHAPe
:
SHAPe
:
A
:
A
:
MODE
:
THD
:
AMP
:
B
:
B
:
MODE
:
THD
:
AMP
VOLTage
[: LEVel][: IMMediate][:AMPLitude]
:
AC
:
DC
:
LIMit
:
AC
:
DC
:
PLUS
:
MINus
:
RANGe
[SOURce :] CURRent : LIMit
Description
: This command sets the rms current limit of the AC source for
software protection.
Query Syntax
: [SOURce :] CURRent : LIMit?
Parameters
: <NR2>, valid range: 0.00 ~ maximum current spec. of the
specific model. (unit: A)
Return Parameters
: <NR2>
[SOURce :] CURRent : DELay
Description
: This command sets the delay time for triggering over current
protection.
Query Syntax
: [SOURce :] CURRent : DELay?
Parameters
: <NR2>, valid range: 0.0 ~ 5.0 (unit: 0.5 second)
Return Parameters
: <NR2>
[SOURce :] CURRent : INRush : STARt
Description
: This command sets the start time of the inrush current
measurement.
Query Syntax
: [SOURce :] CURRent : INRush : STARt?
Summary of Contents for 61501