![Chroma 61501 User Manual Download Page 93](http://html1.mh-extra.com/html/chroma/61501/61501_user-manual_2604431093.webp)
Remote Operation
8-11
OUTPut : SLEW : VOLTage : DC
Description
: This command sets the slew rate of the DC composition
voltage.
Query Syntax
: OUTPut : SLEW : VOLTage : DC?
Parameters
: <NR2>, valid range: 0.000V/ms ~ 1000.000V/ms
Return Parameters
: <NR2>
OUTPut : SLEW : FREQuency
Description
: This command sets the slew rate of the output frequency.
Query Syntax
: OUTPut : SLEW : FREQuency?
Parameters
: <NR2>, valid range: 0.000 Hz/ms ~ 1600.000Hz/ms
Return Parameters
: <NR2>
OUTPut : COUPling
Description
: This command selects the couple setting of the output signal.
Query Syntax
: OUTPut : COUPling?
Parameters
: AC | DC | ACDC
Return Parameters
: AC | DC | ACDC
OUTPut : IMPedance : STATe
Description
: This command enables or disables the output impedance
programming capability of the ac source.
Query Syntax
: OUTPut : IMPedance : STATe?
Parameters :
ON
|
OFF
Return Parameters
: ON | OFF
OUTPut : IMPedance : RESistor
Description
: This command sets the resistance of the output impedance.
Query Syntax
: OUTPut : IMPedance : RESistor?
Parameters
: <NR2>, valid range: 0.00
Ω
~ 1.00
Ω
Return Parameters
: <NR2>
OUTPut : IMPedance : INDuction
Description
: This command sets the induction of the output impedance.
Query Syntax
: OUTPut : IMPedance : INDuction?
Parameters
: <NR2>, valid range: 0.0mH ~ 1.0mH
Return Parameters
: <NR2>
OUTPut : MODE
Description
: This command sets the operation mode. “FIXED” MODE is
normal used.
Query Syntax
: OUTPut : MODE?
Parameters
: FIXED | LIST | PULSE | STEP | SYNTH | INTERHAR
Return Parameters
: FIXED | LIST | PULSE | STEP | SYNTH | INTERHAR
OUTPut : PROTection : CLEar
Description
: This command clears the latch that disables the output when
an overcurrent (OC), overtemperature (OT), overpower (OP) or
remote inhibit (RI) is detected. All conditions which have
generated the faults must be removed before the latch is
cleared.
Query Syntax
: None
Parameters :
None
Return Parameters
: None
Summary of Contents for 61501
Page 1: ...i Programmable AC Source 61501 61502 61503 61504 User s Manual ...
Page 2: ......
Page 3: ...Programmable AC Source 61501 61502 61503 61504 User s Manual Version 1 6 January 2010 ...
Page 7: ...v ...
Page 20: ......
Page 26: ......
Page 28: ...Programmable AC Source 61501 61502 61503 61504 User s Manual 3 2 ...
Page 29: ...Local Operation 3 3 Figure 3 1 ...
Page 56: ......
Page 118: ......
Page 134: ......