Programmable AC Source 61501/61502/61503/61504 User’s Manual
8-26
Query Syntax
: OUTPut : MODE?
Parameters
: FIXED | LIST | PULSE | STEP | SYNTH | INTERHAR
Return Parameters
: FIXED | LIST | PULSE | STEP | SYNTH | INTERHAR
TRIG
Description
: This command sets SYNTHESIS mode in OFF, ON execution
state after setting
OUTPut : MODE SYNTH
. If users want to
change the parameters, it’s necessary to set
TRIG OFF
then
OUTPut : MODE FIXED
.
Then, set
OUTPut : MODE SYNTH
again
to get ready to set
TRIG ON
.
Query Syntax
: TRIG : STATE?
Parameters
: OFF | ON
Return Parameters
: OFF | RUNNING
8.6.2.12 INTERHARMONICS Sub-system
[SOURce :]
INTerharmonics
:
FREQuency
:
STARt
:
END
:
LEVEl
:
DWELl
OUTPut
: MODE
TRIG
TRIG : STATE?
FETCh | MEASure
:
INTerharmonics
:
FREQuency?
Query
the
sweeping
frequency
[SOURce :] INTerharmonics : FREQuency : STARt
Description
: This command starts frequency of the sweep wave of
INTERHARMONICS mode.
Query Syntax
: [SOURce :] INTerharmonics : FREQuency : STARt?
Parameters
: <NR2>, valid range: 0.01 ~ 2400.00 (unit: Hz)
Return Parameters
: <NR2>
[SOURce :] INTerharmonics : FREQuency : END
Description
: This command sets the end frequency of the sweep wave of
INTERHARMONICS mode.
Query Syntax
: [SOURce :] INTerharmonics : FREQuency : END?
Parameters
: <NR2>, valid range: 0.01 ~ 2400.00 (unit: Hz)
Return Parameters
: <NR2>
[SOURce :] INTerharmonics : LEVEl
Description
: This command the r.m.s. magnitude of the sweep wave in
percentage of fundamental.
Query Syntax
: [SOURce :] INTerharmonics : LEVEl?
Summary of Contents for 61501
Page 1: ...i Programmable AC Source 61501 61502 61503 61504 User s Manual ...
Page 2: ......
Page 3: ...Programmable AC Source 61501 61502 61503 61504 User s Manual Version 1 6 January 2010 ...
Page 7: ...v ...
Page 20: ......
Page 26: ......
Page 28: ...Programmable AC Source 61501 61502 61503 61504 User s Manual 3 2 ...
Page 29: ...Local Operation 3 3 Figure 3 1 ...
Page 56: ......
Page 118: ......
Page 134: ......