2. After the DVI-D is connected and the ECU is powered up, the video is enabled by default. Use
the WebUI to control the video content.
Connecting to power
For each MicroTiles array, Christie provides the necessary line cords required for proper power
distribution in your country of origin.
Warning! If not avoided, the following could result in death or serious injury.
•
SHOCK HAZARD! The line cord has a maximum power carrying capability. For the maximum
number of tiles that may be connected per daisy chain when connecting to the power supply,
refer to the product specifications.
Notice. If not avoided, the following could result in property damage.
•
The use of Y-cords may be prohibited due to local or national regulations. An alternative method
of power distribution may be required. This may include Japan, China, Korea and others.
For regions that accept Y-power cords, a Y-Cord Kit can be ordered.
For regions that do not accept Y-power cords an alternate solution is required. For details, see the
Christie MicroTiles Specification and Application Guide (P/N: 020-100334-xx).
The Y-cord Kit does not include line cords (the cords that connect the array to the wall outlet).
Suitable regional line cords must be used.
A quantity of nine Y-cords are shipped with each kit. Multiple tiles are daisy chained to a single power
feed. Up to nine tiles per chain can be supported.
Installation and Setup
Christie MicroTiles Installation and Setup Guide
28
020-100329-15 Rev. 1 (05-2018)
Copyright
©
2018 Christie Digital Systems USA, Inc. All rights reserved.