Daisy Chain Communication
Command data
①
Control the projector
byte_0
byte_1
byte_2
byte_3
byte_4
byte_5
Action
Type
Setting Code
low
high
low
high
low
high
Action (byte_0-1)
Action
Classification
Content
1
Set
Change setting to desired value.
4
Increment
Increment setup value by 1.
5
Decrement
Decrement setup value by 1.
6
Execute
Run a command.
Note: For the Type and Setting Code, see the RS-232C communication/
Network command table (
20
).
②
Get the projector’s status
byte_0
byte_1
byte_2
byte_3
byte_4
byte_5
Action
Type
Connection ID
low
high
low
high
low
high
Action (byte_0-1)
Action
Classification
Content
2
Get
Read projector internal setup value.
Connection ID (byte_4-5)
Connection ID
Content
0~255
This value is attached to the reply data.
③
Other commands
byte_0
byte_1
byte_2
byte_3
byte_4
byte_5
Action
Target Number
Connection ID
low
high
low
high
low
high
Support Command
Action
Target Number Connection ID
Get the number of connected projectors
2
0
0~255
Set the communication Group
identification and Communication ID
1
1~65535
0~255
Get the communication Group
identification and Communication ID
2
1~65535
0~255
Technical Guide
020-000161-01 Rev. 1 (05-2009)