Command
Description
Values
LCB+LOCK <value>
Locks all lens motors preventing the lens from moving.
This overrides all other lens functions.
0 = Unlocks motors (Default)
1 = Locks motors
LCB+ZOMR <value>
Programs the lens connector board lens (LCBL) to
indicate that the lens is motorized or non-motorized.
0 = Lens does not have a zoom
(Default)
1 = Lens has a zoom motor
LCB+ZOOM 1
Calibrates the zoom motor.
1
Examples
Start calibration:
(LCB 1)
Move the lens back to the home position:
(LCB+HOME)
LHO–Lens Horizontal Position Adjustment
Sets the lens horizontal location to an absolute position.
This command is only available when the projector is on.
Commands
Command
Description
Values
LHO?m
Returns the minimum and maximum range of the zoom axis
based on the last lens calibration performed. The returned
range is persistent across AC cycles. (Read-only)
—
LHO
<position>
Adjusts the horizontal location of the lens to the specified
position. The position is persistent across AC cycles.
position = Numeric value subject
to the range returned in LHO?m
Examples
Move the lens to position 500 on the horizontal axis:
(LHO 500)
LMV–Lens Move
Adjusts all aspects of the lens position using a single command.
It can also be used to move the lens to a relative position or to start and stop the motors arbitrarily.
This command is only enabled when the projector is on.
Serial API commands
Crimson and Crimson Mirage Technical Reference–Serial Commands
35
020-102660-01 Rev. 1 (07-2018)
Copyright
©
2018 Christie Digital Systems USA, Inc. All rights reserved.