![Christie BC-RAD 14XA Select User Manual Download Page 14](http://html1.mh-extra.com/html/christie/bc-rad-14xa-select/bc-rad-14xa-select_user-manual_2603568014.webp)
12
INCORRECT
: The foot of the Reaction Arm is too short on the left side, and too long on the right side.
Figure 5.1.3-2: Incorrect Length
Please contact W. Christie (Industrial) LTD for custom Reaction Arms.
5.1.4 – Reaction Points
Ensure the Reaction Arm reacts off the middle of the foot as seen in Figure 5.1.4-1. Do not react off the
heel of the reaction foot as seen in Figure 5.1.4-2.
CORRECT
: Reaction Arm is reacting off the middle of the Reaction Arm’s foot.
Figure 5.1.4-1: Correct Reaction Point
INCORRECT
: Reaction Arm is reacting off the heel of the Reaction Arm. This can cause premature
tool failure.
Figure 5.1.4-2: Incorrect Reaction Point
Summary of Contents for BC-RAD 14XA Select
Page 17: ...15 7 0 CONTACT US ...