![Christ MAGNUM C5X00 Operation Manual Download Page 116](http://html.mh-extra.com/html/christ/magnum-c5x00/magnum-c5x00_operation-manual_2603387116.webp)
Chapter 14
Annexes
116
6501288-EN / 04
Error
Cause
Switching
element
Input
Refer
er-
ence
value
F100: LS length detection not free
Light barriers for length detec-
tion not free, defective or dirty
B10
K0.E42.11
1
F101: LS rear wash not free
Light barriers for rear wash not
free, defective or dirty
B13
K0.E44.12
1
F102: LS signal light stop not free
Light barriers for stop light not
free, defective or dirty
B11
K0.E43.1
1
F103: LS signal light back not free
Light barrier for backward light
not free, defective or dirty
B12
K0.43.2
1
F104: Light barriers not free
Some light barriers are not free
as the unit is switched on.
F143: Meas. value SW2L missing
Power measurement value of
the lateral brush 2 left missing
T62
internal
F144: Meas. value SW2L too high
Power measurement value of
the lateral brush 2 left too high
T62
internal
F145: Idle run SW2L wrong
Idle run of the lateral brush 2 left
wrong
T62
internal
F146: Meas. value SW2R missing
Power measurement value of
the lateral brush 2 right missing
T62
internal
F147: Meas. value SW2R too high
Power measurement value of
the lateral brush 2 right too high
T62
internal
F148: Idle run SW2R wrong
Idle run of the lateral brush 2
right wrong
T62
internal
F167: SW2 blocked
Free drive of the lateral brush 2
impossible
internal
internal
F169: SW2 control error status
Error in the control of the lateral
brushes 2
internal
internal