10
ELECTRICAL CONNECTION
CABLE ENTRY
SYSTEM WIRING DIAGRAM
SINGLE PHASE
THREE PHASE
Connect with min. 18 gauge wire using conduit or gland to
meet min IP55.
Suitable UL listed Liquid Tight Cordgrips (glands) must be
used; cable diameter 0.260” (Minimum) to 0.545” (Maximum).
Connect with min. 18 gauge wire using
conduit or gland to meet minimum IP55 (If
rubber grommet is fitted, remove and
discard to allow use of cable gland).
Sw
GREY
BLUE
RED
L2
F
EARTH
R
L1
Rw
Cr
Cs
RED
BLUE
WHITE
RECS-220P
L2
L1 L2
F
L1
NC- E-STOP
NO- UP
NO-DOWN
Winch Limits
WINCH MOTOR
R
DOWN CONTACTOR
Pre-wired
Installer to wire
UP CONTACTOR
E
Electronic Centrifugal Switch
Controller
SPLIT PHASE MAINS SUPPLY LI-115V, L2-115V
NC
NC
Mains supply 230V/60Hz/3 Phase with No Neutral
E
NC
NC
NC
NO
NO
Winch Limits
DOWN
Contactor
UP
Contactor
E
M
L1 L2 L3 E
Overload
Contactor
Up
Down
E-Stop
L1
L2
L3