9.At the control unit, after clamping the cable to the spring, cut the cable about 8" to 10"
[200 to 250 mm]
longer than necessary. Feed the end of the cable through the center of the spring, around the first insulator on
the control unit, and clamp the cable using the cable clamp supplied with the control unit.
Install the wire form on the control unit insulators. Be sure the guard snaps into the retainers molded into the
10.Install the Poultry Trainer or Line Charger, as shown in
The Poultry Trainer is used to power all
Anti-Roost lines in a house.
•The Line Charger is used to power individual Anti-Roost lines in a house.
•Route the charger wire from the Poultry Trainer or Line Charger to the Anti-Roost system.
•Secure the Charger Wire to the Anti-Roost cable, using a cable clamp.
11.The
anti-roost system
must
be on a
separate electrical circuit, allowing the system to be disconnected
by a switch near the door.
Remember, the anti-roost system should be
grounded through the poultry trainer.
Figure 46.Anti-Roost Installation at the Control Unit
Wire Form
Insulator
Clamp with Anti-Roost
Bracket and Insulator
Clamp
Spring Should be stretched
3/4" to 1" [19mm to 25mm]
Figure 47.Poultry Trainer and Line Charger
Insulated
Secure
Insulated
Anti-Roost
Anti-Roost