Mid-Line Control
31
Installation
Feeder Tube Outlet Holes
New Feeder Lines:
Skip to next section.
Existing Feeder Lines:
Enlarge the outlet
hole to approximately 1''
[2.5 cm]
diameter
for the Mid-Line Control, plus enlarge (2)
outlet holes in front (to the hopper end) of
the Mid-Line Control. Use unibit to enlarge
hole size.
Note: Be sure there are no burrs inside
the tube to catch the auger.
Attaching the Mid-Line Control
Mid-Line Control with Mechanical Switch
1.Remove the two hex head screws on the control top.
2.Lift off the control top.
3.Cradle the feeder tube in the control housing. The feeder tube may have to be turned slightly to allow the
pan to hang straight.
4.Clamp the control in place by inserting tabs on the control top into the slots on the control body. Install and
tighten the two hex head screws previously removed.
Figure 40.Enlarging Outlet Holes
Use a Unibit to enlarge outlet holes on existing
feeder lines.
Auger Tube
Seam
Figure 41.Mid-Line Control Installation
Hex Head Screws
Replace Hex Head Screws
Slots
Feeder Tube