Chore-Time FLEX-IR ST73000 Installation And Operating Instructions Manual Download Page 10

11 

8.

Accessing Setup Menu

Note: Setup is not required for standard operation. 

To access menu mode: 

1. Turn power off to FLEX-IR™.

2. Rotate top knob to zero.

3. Turn power on and rotate top knob to RED ZONE within two seconds of power on.

4. Both Indicator lights will flash three times to indicate menu mode is activated.

To adjust FLEX-IR™ operating parameters: 

1. Rotate bottom knob to feature to be changed.

2. Rotate top knob to desired mode.

3. Feature is changed and locked in when number of blips on top indicator light changes.

TOP 

KNOB 

ALARM RELAY IS ALARM SIGNAL OR RUN 
SIGNAL 

0 = ALARM SIGNAL 

DEFAULT 

1 BLIP 

RED ZONE = RUN SIGNAL 2 BLIPS 

30 

DELAY START AFTER POWERUP CONFIGURE 

0 = 0 SECOND DELAY START 

1 BLIP 

30 = 3 SECOND DELAY START 

DEFAULT 

2 BLIPS 

60 = 6 SECOND DELAY START 

3 BLIPS 

90 = 9 SECOND DELAY START 

4 BLIPS 

120 = 12 SECOND DELAY START 

5 BLIPS 

150 = 15 SECOND DELAY START 

6 BLIPS 

RED ZONE = DELAY START IS WHATEVER KNOB IS SET 
AT 

7 BLIPS 

60 

DELAY START KNOB MINUTES OR SECONDS 

0 = MINUTES 

DEFAULT 

1 BLIP 

RED ZONES = SECONDS 

2 BLIPS 

90 

REMAIN IN MAX TIMED OUT AFTER CYCLING POWER 

0 = YES 

1 BLIP 

RED ZONE = NO 

DEFAULT 

2 BLIPS 

120 

BLANK 

150 

RETURN TO FACTORY SETTINGS YES/NO 

0 = YES 

2 BLIPS (NOTE: Must exit menu through next step and not cycle 

power to lock in factory reset) 

RED ZONE = NO 

1 BLIP 

RED 

ZONE 

EXIT MENU YES/NO 

0 = YES 
RED ZONE = NO 

NOTE: Cycling power will also exit the setup menu. 

BOTTOM

KNOB

Summary of Contents for FLEX-IR ST73000

Page 1: ...FLEX IR Feed System Control Installation and Operating Instructions Item Number ST73000 May 2018 MA FLEXIRGBA1...

Page 2: ...tance of User Installer Manual 4 2 FLEX IR Overview 5 3 Description of Timer Features 5 4 Operating Instructions 5 5 Installation 6 6 FLEX IR WiringDiagrams 8 7 Alarm Connections 9 8 Accessing Setup M...

Page 3: ...accident or lack of proper maintenance shall not be considered defects under thiswarranty 5 This warranty applies only to systems for the care of pork and livestock Other applications in industry or c...

Page 4: ...cial or consequential damages resulting from the use of the information contained in this User Installer Manual The instructions contained in this User Installer Manual are not intended to cover all d...

Page 5: ...r Delay start is the time in minutes from when feed falls away from the sensor until the auger starts This delay prevents short cycling of the system Maximum run time Maximum run time is the amount of...

Page 6: ...IR Feed System Control involves both electrical and tubing applications Installing the tubing Connect the FLEX IR to other feed system components with metal screws or pins In general applications the...

Page 7: ...unit funnel to the feeder is required to be at an angle such as 45 degrees a 45 degree elbow should be placed between the FLEX IR and the power unit funnel An elbow should not be placed between the FL...

Page 8: ...8 6 FLEX IR WIRING DIAGRAMS...

Page 9: ...ems Multiple FLEX IR s may be connected together using the examples below To connect the FLEX IR to the alarm system remove 3 screws and remove the top of the FLEX IR enclosure Use a small screwdriver...

Page 10: ...EFAULT 1 BLIP RED ZONE RUN SIGNAL 2 BLIPS 30 DELAY START AFTER POWERUP CONFIGURE 0 0 SECOND DELAY START 1 BLIP 30 3 SECOND DELAY START DEFAULT 2 BLIPS 60 6 SECOND DELAY START 3 BLIPS 90 9 SECOND DELAY...

Page 11: ...ring Feeders empty and FLEX IR not turning system on System timed out feed bridged below FLEX IR internal or external relay bad Feed goes past FLEX IR and system does not stop Internal or external rel...

Page 12: ...x 800 236 6118 E mail sales pigtek net Internet www pigtekamericas com Printed in the U S A Contact your nearby Chore Time distributor or representative for additional parts and information Distributo...