57" Endura
®
Flush Mount Fan Installation & Operator’s
Fan Shroud Assembly (Unassembled version)
MV2423F
15
Attaching the Fan to the Extension Housing
(shown with doors removed)
Step 1:
Set the Fan on the Bottom Panel
Shelf
as shown
.
Shelf
Eyebolt indicates the
top of the Fan
Step 2:
Attach the Shroud to the Extension Box Panels with 1/4-20 x 7/8" SS Bolt (4404-17) and 1/4-
20 Flange Nuts (46298). Use four Extension Panel Flange Supports (54549)
at Post Corners
as
shown
.
(54549) Flange Support
20x (4404-17)
1/4-20 x 7/8" Bolt
1/4-20 Flange Nut
20x (46298)
Flush
Flush
1/4-20 Flange Nut
(46298)
1/4-20 x 7/8" SS Bolt
(4404-17)
Flange
Support
Use the hole in Flange Supports
that creates flush condition