Installation
57" Flush Mount Direct Drive Endura® Fan
10
Step 4:
Use a Level to level the Side Panels and attach them to the Wall with Screen Clip Washers
(56671)
and 1/4-10 x 1-1/2" Lag Screws
(41561)
as shown
. Angle Lag Screws away from Fan
as shown
on the previous page.
Do not
tighten down the Lag Screws at the Washer locations at
this time. They will be tightened later when the Screen is installed.
Attention!
Do not tighten Lags all the
way at five Washer locations.
(41561)
(56671)
(41561) 1/4-10 x 1-1/2" Lag Screw
Level the Side Panels
(54683) 1/4-20 x 1/2" Screw
Step 5:
Use four Self Tapping Screws
(54683)
to finish fastening the Panels together. Install a Nylon
Cord Clip
(565)
in the top corner nearest where the VFD Control will be mounted
as shown. See
“Fan Drive (VFD) Mounting” on page 17.
(41561)
Attention!
Angle Lags away from Fan at
Washer Locations.
(see previous page)
(56671) Screen Clip Washer
(565)
Nylon Cord Clip