background image

 

Chipkin™

 

™ CAS 2700

 HTTP Push

 

User Manual

 

 

3381 Cambie Street, #211 

© 2018 Chipkin Automation Systems 

Vancouver, BC, Canada, V5Z 4R3 

All rights reserved 

1-866-383-1657  

Chipkin.com

 

Page 7 of 22 

2.

 

CONNECTIONS  

 

NETWORK CONNECTIONS  

This block diagram lists common network connections that can monitor and control data from HTTP 
devices using BACnet IP, Modbus RTU/TCP, etc.  

 

Figure 2.1-1. Network Connections Block Diagram

 

 
 

Summary of Contents for CAS 2700

Page 1: ...Toll Free 1 866 383 1657 3381 Cambie St 211 Vancouver BC Canada V5Z 4R3 Chipkin CAS 2700 HTTP Push USER MANUAL VERSION 0 08 PRODUCT NUMBER CAS 2700 DOCUMENT REVISION 1...

Page 2: ...TABLES 3 COPYRIGHT TRADEMARKS 4 DISCLAIMER 4 CONFIDENTIALITY 4 DOCUMENT REVISION HISTORY 4 1 PREFACE 5 WELCOME 5 CHIPKIN 5 SAFETY WARNINGS 5 CUSTOMER SUPPORT 5 2 CONNECTIONS 7 NETWORK CONNECTIONS 7 CO...

Page 3: ...18 Chipkin Automation Systems Vancouver BC Canada V5Z 4R3 All rights reserved 1 866 383 1657 Chipkin com Page 3 of 22 LIST OF FIGURES Figure 3 1 1 Network Connections Block Diagram 7 LIST OF TABLES Ta...

Page 4: ...ge the contents of this user manual at any time without notice and assumes no liability for its accuracy In the preparation of this user manual Chipkin Automation Systems has incorporated and or compi...

Page 5: ...ides expert solutions for converting BACnet Modbus and Lonworks to name just a few and enabling interfaces for HVAC fire siren intercom lighting transportation and fuel systems The high quality produc...

Page 6: ...a V5Z 4R3 All rights reserved 1 866 383 1657 Chipkin com Page 6 of 22 SALES AND CUSTOMER SUPPORT TOLL FREE 1 866 383 1657 FAX 1 416 915 4024 EMAIL salesgroup1 chipkin com GENERAL TOLL FREE 1 866 383 1...

Page 7: ...er BC Canada V5Z 4R3 All rights reserved 1 866 383 1657 Chipkin com Page 7 of 22 2 CONNECTIONS NETWORK CONNECTIONS This block diagram lists common network connections that can monitor and control data...

Page 8: ...1 866 383 1657 Chipkin com Page 8 of 22 COMUNCATION PORTS The Gateway uses the following ports for communication Protocol Port Notes HTTP TCP 80 Web server BACnet IP UDP 47808 Default port can be conf...

Page 9: ...P Put or HTTP Post payloads The current driver contains only two options for payloads Default JSON or Veeder JSON These will be described in more detail below If a specific format is required JSON XML...

Page 10: ...ush User Manual 3381 Cambie Street 211 2018 Chipkin Automation Systems Vancouver BC Canada V5Z 4R3 All rights reserved 1 866 383 1657 Chipkin com Page 10 of 22 You will see the following page Figure 3...

Page 11: ...66 383 1657 Chipkin com Page 11 of 22 End Point Configuration First add an end point Click on the End Points insert link to add a new end point Figure 3 1 1 End Point Insert Link You will see the foll...

Page 12: ...erved 1 866 383 1657 Chipkin com Page 12 of 22 Port The port to use when pushing data Default 80 Url The url end point of where to send the data payload Once the fields are filled click the Add End Po...

Page 13: ...ver BC Canada V5Z 4R3 All rights reserved 1 866 383 1657 Chipkin com Page 13 of 22 Method and Headers Configuration Next add a method and headers to the end point Click on the Methods and Headers inse...

Page 14: ...V5Z 4R3 All rights reserved 1 866 383 1657 Chipkin com Page 14 of 22 Figure 3 2 2 Method and Headers Form Select End Point First select the End Point to use from the drop down box This will include a...

Page 15: ...any headers that are required for sending the data payload These headers are stored as a JSON object and must conform to JSON spec When adding additional headers make sure each header is on a new line...

Page 16: ...HTTP Push User Manual 3381 Cambie Street 211 2018 Chipkin Automation Systems Vancouver BC Canada V5Z 4R3 All rights reserved 1 866 383 1657 Chipkin com Page 16 of 22 Figure 3 2 3 Method and Header ad...

Page 17: ...e 17 of 22 Task Configuration Finally add tasks that will package the data and send the payload To add a task click on the Task Configuration Insert link as seen below Figure 3 3 1 Tasks Insert Link D...

Page 18: ...out the form with the following fields Task Name The name of the task this is used just for identification Data Table The data table where the data is stored Default da_data Data Offset The index in...

Page 19: ...211 2018 Chipkin Automation Systems Vancouver BC Canada V5Z 4R3 All rights reserved 1 866 383 1657 Chipkin com Page 19 of 22 Figure 3 3 3 Default JSON Task added successfully VeederRoot JSON If using...

Page 20: ...the End Point and Method of where the data will be pushed Next fill out the Frequency field to specify how often in seconds to push the data Finally select the Veeder Root Tank data to send Note Ther...

Page 21: ...TTP Push User Manual 3381 Cambie Street 211 2018 Chipkin Automation Systems Vancouver BC Canada V5Z 4R3 All rights reserved 1 866 383 1657 Chipkin com Page 21 of 22 Figure 3 3 5 VeederRoot JSON Task a...

Page 22: ...rks to name just a few and enabling interfaces for HVAC fire siren intercom lighting transportation and fuel systems The high quality products we offer including those from other vendors interface wit...

Reviews: