c.Basic functions
Controller type
Standard (M type)
Three cascades
protection
Communication (H type)
Basic
function
Long time-delay protection
Short time-delay protection
Instantaneous protection
Earthing fault protection
Load current display
Load current digital display (Ampere Meter)
Test function
Fault recall
Self-diagnose function
MCR making and breaking function
Fault alarm
Fault breaking indication
Customer setting, testing
Load monitor
RS485 port MODBUS protocol
Voltage measuring
Frequency display
Active power measuring
Power factor measuring
Electric energy measuring
Over voltage protection
Under voltage protection
Phase protection
Current transformer earthing protection
Exceed breaking function
Thermal recall fuction
Four output contacts
Optional
auxiliary
function
Man-machine interface instruction
Four cascades
protection
Three cascades
protection
Four cascades
protection
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
■ (
3P+N model)
■ (
3P+N model)
■
■
■
■
■
■
■
■
■
■
■
■
■
■
LED display, code switch and
toggle switch setting
LCD display, LED indication,
keyboard operation
●
stands for definite setting
■
stands for optional setting
—
stands for no funcion
d.Operation instructions
Standard intelligent controller setting
According to the panel number 9 showed, dial the switch 11,14,20 to set the time you need.
According to the panel number 10 showed, dial the switch 12,15,17,19 to set the current you need.
Example 1: means that overload long time-delay current is 0.9In, overload long time-delay time is 60s.
Example 2: means that short circuit short time-delay current is 4In, short circuit short time-delay time is 0.4s.
Ir
tr
Isd
tsd
Example 1
Example 2
Communication intelligent controller setting and operation.
It provides 4 main menu and 1 default interface.
Default interface
Without other function action, it displays phases current column chart.
547 A
A
B
C
N
150
100
50
0
“Testing” menu
Harmonic
wave H
Press or key to return default interface.
On other non-fault interface, press to skip to testing menu.
Without action for several minutes, it return to the default interface.
“System data setting” menu
Press or key to return default interface..
On other non-fault interface, press to skip to system data setting menu.
Without action for several minutes, it return to the default interface.
“
Protection data setting” menu
Press or key to return default interface.
On other non-fault interface, press to skip to protection data setting menu.
Without action for several minutes, it return to the default interface.
Air Circuit Breaker
Current I
Voltage U
Frequency F
Power P
Electric energe E
Clock setting
Measure metre setting
Testing lock
Communication setting
I/O setting
Current protection
Load monitor
Voltage protecting
Other protection