3.2 Installation
The external and mounting dimensions are shown below. Fix the detector unit with 2 pieces of
M20 bolts to a fixing plate like a mounting angle, a mounting plate, etc. so that the
measurement window is parallel to a measuring area and is positioned with the center line of a
measuring area.
The measurement distance of the detector unit can be arbitrarily changed in 0.5 to 10m. When
the installation is completed, perform the distance setting by turning the distance setting axis.
When the protective case and the air-purge hood are used, refer to the paragraphs shown
below.
x
Protective case
x
x
x
Refer to [4.1 Protective case Model: IR-ZEPW].
x
Air-purge hood
x
x
x
Refer to [4.2 Air-purge hood Model: IR-ZEAH].
3. Detector unit
20
(25
)
200
120
60
410
450
50°
370
In case of connector connection
Unit: mm