Seasonal Switch Valve
The G3 port can be used to control a seasonal switch valve. The seasonal switch valve is
used to isolate the floor coils (if needed) from the fan coils when switching over from
heating to cooling. The seasonal switch valve is controlled by parameter 14. When
parameter 14 is 0, the valve is configured as a seasonal Switch. When parameter 14 is
1, the valve is configured as a solar pre-heat valve. See detailed wiring diagram on the
next page.